Troubleshooting

Table 9 provides a detailed description of the fault messages and solutions. If you are unable to resolve the problem after referring to this table, contact your dealer or Customer Service.

Table 9 Fault Messages

Fault

 

 

 

 

Number

Message

Fault Type

Cause

Solution

 

 

 

 

 

F0

Unit is too hot and has shut

Automatic

FET1 Over Temperature

Clear the fault and attempt restart. Ensure

 

down. See guide.

 

Shutdown

adequate ventilation around the Freedom

 

 

 

 

SW 3000. Reduce AC loads.

 

 

 

 

 

F2

Unit is too hot and has shut

Automatic

FET2 Over Temperature

Clear the fault and attempt restart. Ensure

 

down. See guide.

 

Shutdown

adequate ventilation around the Freedom

 

 

 

 

SW 3000. Reduce AC loads.

 

 

 

 

 

F3

Unit is too hot and has shut

Automatic

Transformer Over

Clear the fault and attempt restart. Ensure

 

down. See guide.

 

Temperature Shutdown

adequate ventilation around the Freedom

 

 

 

 

SW 3000. Reduce AC loads.

 

 

 

 

 

F4

Battery over-temp. Inv/Chg

Automatic

Battery Over Temperature

Clear the fault and attempt restart. Stop

 

has shut down. See guide.

 

Shutdown

charging, check battery voltage and

 

 

 

 

temperature. Check for excessive ambient

 

 

 

 

temperature and adequate ventilation in

 

 

 

 

the battery compartment.

 

 

 

 

 

F5

is too hot and has shut

Automatic

Ambient Over Temperature

Clear the fault and attempt restart. Ensure

 

down. See guide.

 

Shutdown

adequate ventilation around Freedom SW

 

 

 

 

3000. Reduce AC loads.

 

 

 

 

 

975-0545-01-01

51

Page 65
Image 65
Xantrex Technology SW 3000 user service Fault Number Message Fault Type Cause Solution