Troubleshooting
Table 9 Fault Messages
Fault |
|
|
|
|
Number | Message | Fault Type | Cause | Solution |
|
|
|
|
|
F24 | Inverter/Charger internal | Escalating Auto Fault. | AC Under Voltage | Service required. |
| failure. Service required. | Must occur 3 times in 60 | Shutdown (Inverter AC |
|
|
| seconds before becoming a | output) |
|
|
| manual fault. |
|
|
|
|
|
|
|
F29 | AC Backfeed fault: Service | Manual | AC Backfeed Shutdown | Service required. |
| immediately. |
|
|
|
|
|
|
|
|
F30 | Unit is too cold and has | Manual | Battery Under Temperature | Clear the fault and attempt one restart. Try |
| shut down. See guide. |
| Fault | restart again when ambient temperature is |
|
|
|
| warmer or gently warm the battery. |
|
|
|
|
|
F40 | Internal fault. If fault | Manual | No IPC communication | Service required. |
| persists, call Customer |
|
|
|
| Support. |
|
|
|
|
|
|
|
|
F41 | Internal fault. Reset. If fault | Manual | Dead battery charger | Try restarting dead battery charging once. |
| persists, call Customer |
| timeout | Then check the condition of the battery |
| Support. |
|
| and replace if necessary. |
|
|
|
|
|
F502 | Watchdog reset error | Manual | Watchdog reset error | Service required. |
|
|
|
|
|
F505 | Controller fault | Manual | Controller fault | Service required. |
|
|
|
|
|
F506 | Wrong fault identifier | Manual | Wrong fault identifier | Service required. |
|
|
|
|
|
F507 | Wrong identifier | Manual | Wrong identifier | Service required. |
|
|
|
|
|
53 |