Troubleshooting

Table 9 Fault Messages

Fault

 

 

 

 

Number

Message

Fault Type

Cause

Solution

 

 

 

 

 

F6

Too many AC loads. Turn

Escalating Auto Fault.

AC Overload Shutdown

Clear the fault and attempt restart. Reduce

 

some off, clear fault, try

Must occur 3 times in 30

(AC OUTPUT)

AC loads.

 

again.

seconds before becoming a

 

Check that AC input wiring is not

 

 

manual fault.

 

connected to the AC output.

 

 

 

 

 

F9

Battery voltage is too high.

Automatic

DC Over Voltage

Clear the fault and attempt restart. Ensure

 

See guide.

 

Shutdown

battery voltage is 10–16 VDC at Freedom

 

 

 

 

SW 3000 terminals. Check all other

 

 

 

 

charging source outputs, battery cables.

 

 

 

 

 

F10

Battery is too low, can’t

Automatic

DC Under Voltage

Clear the fault and attempt restart.

 

invert. Recharge battery.

 

Shutdown (Immediate)

Recharge batteries. Check battery cable

 

 

 

occurs if DC voltage is

connections.

 

 

 

below 8 volts DC

 

 

 

 

 

 

F11

Battery is too low, can’t

Automatic

DC Under Voltage

Clear the fault and attempt restart.

 

invert. Recharge battery.

 

Shutdown occurs if DC

Recharge batteries. Check battery cable

 

 

 

voltage is below 10 volts

connections.

 

 

 

DC.

 

 

 

 

 

 

F23

Inverter/Charger internal

Escalating Auto Fault.

AC Over Voltage

Service required.

 

failure. Service required.

Must occur 3 times in 30

Shutdown (Inverter AC

 

 

 

seconds before becoming a

output)

 

 

 

manual fault.

 

 

 

 

 

 

 

52

Freedom SW 3000 Owner’s Guide

Page 66
Image 66
Xantrex Technology SW 3000 user service AC Output