Operating The Freedom SW 3000

Monitoring the Freedom SW 3000 Indicator Lights

The ten indicator lights on the front panel show you the operating status of the Freedom SW 3000. A description of the lights is provided in Table 3.

If none of the front panel lights are on, see “Troubleshooting Reference” on page 47.

Table 3 Front Panel Lights

 

Light

 

 

 

 

 

 

Illuminated

Color

Status

Action or Status Item

 

 

 

 

AC Charge

Green

When the Freedom

You can run your

 

 

SW 3000 is connected

appliances from an

 

 

to a qualified AC

AC source like the

 

 

source or a generator,

utility grid or a

 

 

the External AC light

generator.

 

 

illuminates.

 

Inverter

Green

When inverter mode is

You can run your

Enable

 

enabled, the Inverter

appliances from the

 

 

Enable Light is

inverter.

 

 

illuminated. If Utility

 

 

 

is unavailable and

 

 

 

operating conditions

 

 

 

are met, the Freedom

 

 

 

SW 3000 will produce

 

 

 

AC voltage to power

 

 

 

your loads.

 

Table 3 Front Panel Lights

 

Light

 

 

 

 

 

 

Illuminated

Color

Status

Action or Status Item

 

 

 

 

Fault

Red

A fault has occurred

Investigate and clear

 

 

on the network.

the fault condition.

Faults and Warnings

A fault affects the operation of the unit. A manual fault requires user intervention by clearing the condition and then pressing the Reset button on the inverter/charger’s front panel. See the System Control Panel Owner’s Guide for information on clearing faults from the SCP.

A warning alerts you to a condition that could possibly affect operation of the unit.

See “Faults and Warnings” on page 21 for more explanation on the difference between faults and warnings.

Monitoring Status Messages on the SCP

Refer to “System Menu Map” on page 26 of the Configuration chapter.