Primary Processor Test Error Codes
The 100 series of Diagnostic error codes identifies failures with processor and system board functions.
Table
Primary Processor Test Error Codes
Error Code
Description
CPU test failed
DMA page registers test failed. Interrupt controller master test failed. Port 61 error.
Keyboard controller
CMOS RAM test failed. CMOS interrupt test failed. CMOS clock load data test failed.
Programmable timer load data test failed. Refresh detect test failed.
Speed test slow mode out of range. Protected mode test failed. Speaker test failed.
Cache test failed.
Multiprocessor Dispatch test failed. Interprocessor Communication test failed.
Installed devices test failed.
Recommended Action
Replace the processor board and retest.
For error codes
The following steps apply to error codes
Replace the battery/clock module and retest. Replace the system board and retest.
For error codes
1.Verify the speaker connection and retest.
2.Replace the speaker and retest.
3.Replace the system board and retest. Replace the system board and retest.
The following steps apply to error codes 122-xx through 123-xx:
Check the system configuration and retest. Replace the processor board and retest. Replace the system board and retest.
1.Check the system configuration and retest.
2.Verify cable connections and retest.
3.Check switch and/or jumper settings and retest.
4.Run the Configuration utility and retest.
5.Replace the processor board and retest.
6.Replace the system board and retest.
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater