Compaq 113803-001 Slot x Drive, SMART-2 Controller error, Progress, Array Drives, Port Address

Models: 113803-001

1 162
Download 162 pages 24.35 Kb
Page 68
Image 68

 

 

 

 

 

 

3-11

POST Error Messages Continued

 

 

 

 

 

 

 

Audible Beeps

 

 

 

 

Error Code

 

 

L=Long S=Short

 

Probable Source of Problem

 

Recommended Action

1768-Slot x Drive

 

None

 

SMART-2 Controller error

 

No action required. Appears whenever

Array -Resuming

 

 

 

 

 

a controller reset or power cycle

logical drive

 

 

 

 

 

occurs while array expansion is in

expansion process.

 

 

 

 

 

progress.

 

 

 

 

 

 

 

 

1769-Slot x Drive

 

None

 

SMART-2 Controller error.

 

Data has been lost while expanding the

Array - Drive(s)

 

 

 

 

 

array, therefore the drives have been

disabled due to failure

 

 

 

 

 

temporarily disabled. Press F2 to

during expand. Select

 

 

 

 

 

accept the data loss and re-enable the

F1 to continue with

 

 

 

 

 

logical drives. Restore data from

logical drives

 

 

 

 

 

backup.

disabled. Select F2 to

 

 

 

 

 

 

accept data loss and

 

 

 

 

 

 

to re-enable logical

 

 

 

 

 

 

drives.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1771-Primary Disk

None

Internal and external hard drive

Port Address

 

controllers are both assigned

Assignment Conflict

 

to the primary address.

 

 

 

1772-Secondary Disk

None

Address Assignment Conflict.

Port Address

 

Internal and external hard drive

Assignment Conflict

 

controllers are both assigned

 

 

to the secondary address.

 

 

 

1773-Primary Fixed

None

Fixed disk drive error.

Disk Port Assignment

 

 

Conflict

 

 

 

 

 

1774-Slot x Drive

None

SMART-2 Controller error.

Array - Obsolete data

 

 

found in Array

 

 

Accelerator. Select F1

 

 

to discard contents of

 

 

Array Accelerator.

 

 

Select F2 to write

 

 

contents of Array

 

 

Accelerator to drives.

 

 

 

 

 

Run the System Configuration Utility and correct.

Run the System Configuration Utility and correct.

Run the System Configuration Utility and correct.

Data found in Array Accelerator is older than data found on drives. Press F1 to discard the older data in the Array Accelerator and retain the newer data on the drives.

1776-Drive Array -

None

External and internal SCSI

SCSI Port Termination

 

drives are both configured to

Error

 

Port 1.

 

 

 

1777-Drive Array

None

Cooling fan failure, internal

External Drive

 

temperature alert or open side

Subsystem Error

 

panel.

 

 

 

Reconfigure drives.

Inspect for cooling fan failure or open side panel.

Continued

Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

Page 68
Image 68
Compaq 113803-001 manual Slot x Drive, SMART-2 Controller error, Progress, Array Drives, Temporarily disabled. Press F2 to