2-1

Chapter 2

Removal and Replacement Procedures

This chapter provides subassembly/module-level removal and replacement procedures for ProLiant 3000 Servers. After completing all necessary removal and replacement procedures, run the Diagnostics program to verify that all components operate properly.

To service Compaq ProLiant 3000 Servers, the following tools are recommended:

Torx T-15 screwdriver

Torx T-25 screwdriver

Phillips screwdriver

From the Compaq SmartStart and Support Software CD:

System Configuration Utility software

Drive Array Advanced Diagnostics software

Diagnostics software

Electrostatic Discharge Information

A discharge of static electricity can damage static-sensitive devices or microcircuitry. Proper packaging and grounding techniques are necessary precautions to prevent damage. To prevent electrostatic damage, observe the following precautions:

Transport products in static-safe containers such as conductive tubes, bags, or boxes.

Keep electrostatic-sensitive parts in their containers until they arrive at static- free stations.

Cover workstations with approved static-dissipating material. Provide a wrist strap connected to the work surface and properly grounded tools and equipment.

Keep work area free of non-conductive materials such as ordinary plastic assembly aids and foam packing.

Make sure you are properly grounded when touching a static-sensitive component or ssembly.

Avoid touching pins, leads, or circuitry.

Always place drives PCB assembly-side down.

Use conductive field service tools.

Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

Page 14
Image 14
Compaq 113803-001 manual Removal and Replacement Procedures, Electrostatic Discharge Information