3-36Diagnostic Tools

DAAD Diagnostic Messages

Table 3-21 lists DAAD diagnostic messages in alphabetical order.

Table 3-21

DAAD Diagnostic Messages

Message

Accelerator board not detected

Description

Array controller did not detect a configured array accelerator board.

Recommended Action

Install array accelerator board on array controller. If an array accelerator board is installed, check for proper seating on the array controller board. You may need to run the System Configuration Utility and disable the array accelerator board to get this message off the screen.

Accelerator error

List of the last 32 parity errors on

log

transfers to or from memory on the

 

array accelerator board. Displays

 

starting memory address, transfer

 

count, and operation (read and write).

 

 

If there are many parity errors, you may need to replace the array accelerator board.

Accelerator parity

Number of times that read memory

read errors: n

parity errors were detected during

 

transfers from memory on array

 

accelerator board.

 

 

Accelerator parity

Number of times that write memory

write errors: n

parity errors were detected during

 

transfers to memory on the array

 

accelerator board.

 

 

If there are many parity errors, you may need to replace the array accelerator board.

If there are many parity errors, you may need to replace the array accelerator board.

Accelerator status: Permanently disabled

Accelerator status: Possible data loss in cache

Array accelerator board has been permanently disabled. It remains disabled until it is reinitialized using the System Configuration Utility.

Possible data loss detected during power-up due to all batteries being below sufficient voltage level and no presence of identification signatures on the array accelerator board.

Check the Disable Code field. Run the System Configuration Utility to reinitialize the array accelerator board.

There is no way to determine if dirty or bad data was in the cache and is now lost.

Accelerator status: Temporarily disabled

Accelerator status: Unrecognized status

Array accelerator board has been temporarily disabled.

A status returned from the array accelerator board that DAAD does not recognize.

Check the Disable Code field.

Obtain the latest version of DAAD.