POST Error Messages Continued

 

 

Audible Beeps

 

 

Error Code

 

L=Long S=Short

 

Probable Source of Problem

162-System Options

 

2S

 

Configuration incorrect.

Not Set

 

 

 

 

 

 

 

 

 

163-Time & Date

 

2S

 

Invalid time or date in

Not Set

 

 

 

configuration memory.

 

 

 

 

 

170-Expansion

 

None

 

EISA or PCI expansion board

Device Not

 

 

 

failure.

Responding

 

 

 

 

 

 

 

 

 

172-Configuration

 

None

 

Nonvolatile configuration

Nonvolatile Memory

 

 

 

corrupt or jumper installed.

Invalid

 

 

 

 

 

 

 

 

 

172-1 Configuration

 

None

 

Nonvolatile configuration

Nonvolatile Memory

 

 

 

corrupt.

Invalid

 

 

 

 

 

 

 

 

 

172-2 IRC

 

None

 

IRC enabled and video

Configuration Invalid

 

 

 

controller is in PCI slot on the

 

 

 

 

secondary bus.

 

 

 

 

 

173-Slot ID

 

None

 

Board replaced, configuration

Mismatch

 

 

 

not updated.

 

 

 

 

 

174-

 

None

 

EISA or PCI board not found.

Configuration/Slot

 

 

 

 

Mismatch Device

 

 

 

 

Not Found

 

 

 

 

 

 

 

 

 

3-5

Recommended Action

Run the System Configuration Utility and correct.

Run the System Configuration Utility and correct.

Check board for secure installation. Replace the failed board if necessary.

Run the System Configuration Utility and correct.

Run the System Configuration Utility and correct.

Move video controller to a PCI slot on the primary PCI bus.

Run the System Configuration Utility and correct.

Run the System Configuration Utility and correct.

175-

None

EISA or PCI board added,

Configuration/Slot

 

configuration not updated.

Mismatch Device

 

 

Found

 

 

 

 

 

Run the System Configuration Utility and correct.

176-Slot with Not

None

EISA or PCI board in slot that

Run the System Configuration Utility

Readable ID Yields

 

should contain an ISA board.

and correct.

Valid ID

 

 

 

 

 

 

 

177-Configuration

None

Incomplete System

Run the System Configuration Utility

Not Complete

 

Configuration.

and correct.

 

 

 

 

178-Processor

None

Processor type or step does not

Run the System Configuration Utility

Configuration Invalid

 

match configuration memory.

and correct.

 

 

 

 

179-System

None

A board was installed that has a

Run the System Configuration Utility

Revision Mismatch

 

different revision date.

and correct.

 

 

 

 

180-Log Reinitialized

None

N/A

N/A

 

 

 

 

 

 

 