DAAD Diagnostic Messages Continued
Message
Logical Drive X status = WRONG DRIVE REPLACED
Loose cable detected - logical drives may be marked FAILED until corrected
Mirror data miscompare
Description
A physical drive in this logical drive has failed. The incorrect drive was replaced.
Controller unable to communicate with one or more physical drives, probably because of a cabling problem. Logical drives may be in a FAILED state until the condition is corrected, preventing access to data on the controller.
Data was found at reinitialization in the posted write memory; however, the mirror data compare test failed resulting in data being marked as invalid. Data loss is possible.
Recommended Action
Replace the drive that was incorrectly replaced. Then, replace the original drive that failed with a new drive. Do not run the System Configuration Utility to reconfigure; you will lose data on the drive.
Check all controller and drive cable connections.
Replace the array accelerator board.
Mirrored memory | Soft errors occurred when attempting to Replace the array accelerator board. |
location errors | read the same data from both sides of |
| the mirrored memory. Data loss will |
| occur. |
|
|
No configuration for Accelerator Board
SCSI port X, drive ID Y firmware needs upgrading
Set configuration command issued
The array accelerator board has not been configured.
Drive’s firmware may cause problems and should be upgraded.
The configuration of the array controller has been updated. The array accelerator board may remain disabled until it is reinitialized.
If the array accelerator board is present, run the System Configuration Utility to configure the board, if desired.
Run Options ROMPaq to upgrade the drive’s firmware to a later revision.
Run the System Configuration Utility to reinitialize the array accelerator board.
Soft Firmware Upgrade required
DAAD has determined that your | Run the Compaq Upgrade Utility to place the latest |
controller is running firmware that has | firmware on all drives. |
been soft upgraded by the Compaq |
|
Upgrade Utility. However, the firmware |
|
running is not present on all drives. This |
|
could be caused by the addition of new |
|
drives in the system. |
|
|
|
Threshold for | This message indicates that a monitor |
drive (bay) X | and performance threshold for this drive |
violated | has been violated. |
Check for the particular threshold that has been violated.
Continued