3-44Diagnostic Tools

DAAD Diagnostic Messages Continued

Message

Logical Drive X status = WRONG DRIVE REPLACED

Loose cable detected - logical drives may be marked FAILED until corrected

Mirror data miscompare

Description

A physical drive in this logical drive has failed. The incorrect drive was replaced.

Controller unable to communicate with one or more physical drives, probably because of a cabling problem. Logical drives may be in a FAILED state until the condition is corrected, preventing access to data on the controller.

Data was found at reinitialization in the posted write memory; however, the mirror data compare test failed resulting in data being marked as invalid. Data loss is possible.

Recommended Action

Replace the drive that was incorrectly replaced. Then, replace the original drive that failed with a new drive. Do not run the System Configuration Utility to reconfigure; you will lose data on the drive.

Check all controller and drive cable connections.

Replace the array accelerator board.

Mirrored memory

Soft errors occurred when attempting to Replace the array accelerator board.

location errors

read the same data from both sides of

 

the mirrored memory. Data loss will

 

occur.

 

 

No configuration for Accelerator Board

SCSI port X, drive ID Y firmware needs upgrading

Set configuration command issued

The array accelerator board has not been configured.

Drive’s firmware may cause problems and should be upgraded.

The configuration of the array controller has been updated. The array accelerator board may remain disabled until it is reinitialized.

If the array accelerator board is present, run the System Configuration Utility to configure the board, if desired.

Run Options ROMPaq to upgrade the drive’s firmware to a later revision.

Run the System Configuration Utility to reinitialize the array accelerator board.

Soft Firmware Upgrade required

DAAD has determined that your

Run the Compaq Upgrade Utility to place the latest

controller is running firmware that has

firmware on all drives.

been soft upgraded by the Compaq

 

Upgrade Utility. However, the firmware

 

running is not present on all drives. This

 

could be caused by the addition of new

 

drives in the system.

 

 

 

Threshold for

This message indicates that a monitor

drive (bay) X

and performance threshold for this drive

violated

has been violated.

Check for the particular threshold that has been violated.

Continued

Page 101
Image 101
Compaq 113803-001 Array accelerator board has not been configured, Daad has determined that your, Firmware on all drives