DAAD Diagnostic Messages Continued
Message |
| Description |
Configuration |
| DAAD detected that nonvolatile RAM |
signature is zero |
| contains a configuration signature that is |
|
| zero. Old versions of the System |
|
| Configuration Utility could cause this. |
|
|
|
Recommended Action
Run the latest version of System Configuration Utility to configure the controller and nonvolatile RAM.
Configuration | Array accelerator board configured for a |
signature | different array controller board. |
mismatch | Configuration signature on array |
| accelerator board does not match the one |
| stored on the array controller board. |
|
|
To recognize the array accelerator board, run the System Configuration Utility.
Controller communication failure occurred
Controller detected. NVRAM configuration not present
Controller firmware needs upgrading
Controller firmware needs upgrading (DAAD Error 102)
Controller is located in special “video” slot
Controller is not configured
Controller needs replacing (DAAD Error 102)
Controller communication failure occurred.
EISA nonvolatile RAM does not contain a configuration for this controller.
Controller firmware is below the latest recommended version.
Controller is correct, however, IDA firmware version should be greater than 1.26.
Controller is installed in slot for special video control signals. If controller is used in this slot, LED indicators on front panel may not function properly.
Controller is not configured. If controller was previously configured and you change drive locations, there may be a problem with placement of the drives. DAAD examines each physical drive and looks for drives that have been moved to a different drive bay.
IDA firmware is less than version 0.96.
DAAD was unable to successfully issue commands to the controller in this slot.
Run the System Configuration Utility to configure the nonvolatile RAM.
Run Options ROMPaq to upgrade the controller to the latest firmware revision.
Obtain the latest firmware.
Install the controller in a different slot and run the System Configuration Utility to configure the controller and nonvolatile RAM.
Look for messages indicating which drives have been moved. If none appear and drive swapping did not occur, run the System Configuration Utility to configure the controller and nonvolatile RAM. Do not run the System Configuration Utility if you believe drive swapping has occurred.
Replace the controller as soon as possible.
Continued
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater