DAAD Diagnostic Messages Continued

Message

 

Description

Configuration

 

DAAD detected that nonvolatile RAM

signature is zero

 

contains a configuration signature that is

 

 

zero. Old versions of the System

 

 

Configuration Utility could cause this.

 

 

 

3-39

Recommended Action

Run the latest version of System Configuration Utility to configure the controller and nonvolatile RAM.

Configuration

Array accelerator board configured for a

signature

different array controller board.

mismatch

Configuration signature on array

 

accelerator board does not match the one

 

stored on the array controller board.

 

 

To recognize the array accelerator board, run the System Configuration Utility.

Controller communication failure occurred

Controller detected. NVRAM configuration not present

Controller firmware needs upgrading

Controller firmware needs upgrading (DAAD Error 102)

Controller is located in special “video” slot

Controller is not configured

Controller needs replacing (DAAD Error 102)

Controller communication failure occurred.

EISA nonvolatile RAM does not contain a configuration for this controller.

Controller firmware is below the latest recommended version.

Controller is correct, however, IDA firmware version should be greater than 1.26.

Controller is installed in slot for special video control signals. If controller is used in this slot, LED indicators on front panel may not function properly.

Controller is not configured. If controller was previously configured and you change drive locations, there may be a problem with placement of the drives. DAAD examines each physical drive and looks for drives that have been moved to a different drive bay.

IDA firmware is less than version 0.96.

DAAD was unable to successfully issue commands to the controller in this slot.

Run the System Configuration Utility to configure the nonvolatile RAM.

Run Options ROMPaq to upgrade the controller to the latest firmware revision.

Obtain the latest firmware.

Install the controller in a different slot and run the System Configuration Utility to configure the controller and nonvolatile RAM.

Look for messages indicating which drives have been moved. If none appear and drive swapping did not occur, run the System Configuration Utility to configure the controller and nonvolatile RAM. Do not run the System Configuration Utility if you believe drive swapping has occurred.

Replace the controller as soon as possible.