3-31

SCSI Hard Drive Test Error Codes

The 6500 series of Diagnostic error codes identifies failures with SCSI hard drives, SCSI hard drive controller boards, SCSI hard drive cabling, and system board functions. If your system uses a drive array controller, see the section for Drive Array Advanced Diagnostics (DAAD).

Table 3-16

SCSI Hard Drive Test Error Codes

Error Code

6500-xx

6502-xx

6505-xx

6506-xx

6509-xx

6523-xx

6528-xx

Description

SCSI Disk ID drive types test failed.

SCSI Disk Unconditional Format test failed. SCSI Disk Read Test Failed.

SCSI Disk SA/Media test failed. SCSI Disk Erase tape test failed. SCSI Disk Random Read test failed. Media load/unload test failed.

Recommended Action

1.Run the System Configuration Utility and verify the drive type.

2.Replace the SCSI disk drive signal and power cables and retest.

3.Replace the SCSI controller and retest.

4.Replace the SCSI disk drive and retest.

5.Replace the system board and retest.

SCSI/IDE CD-ROM Drive Test Error Codes

The 6600 series of Diagnostic error codes identifies failures with the CD-ROM cabling, CD-ROM drives, adapter boards, or the system board assembly.

Table 3-17

SCSI/IDE CD-ROM Drive Test Error Codes

Error Code

Description

 

 

 

6600-xx

CD-ROM ID failed.

6605-xx

CD-ROM Read failed.

Recommended Action

1.Replace the CD-ROM media and retest.

2.Check and/or replace the signal cable and retest.

3.Check the switch settings on the adapter board (if applicable).

4.Replace the SCSI controller (if applicable) and retest.

5.Replace the CD-ROM drive and retest.

6.Replace the system board and retest.

Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

Page 88
Image 88
Compaq 113803-001 manual Scsi Hard Drive Test Error Codes, SCSI/IDE CD-ROM Drive Test Error Codes