SCSI Hard Drive Test Error Codes
The 6500 series of Diagnostic error codes identifies failures with SCSI hard drives, SCSI hard drive controller boards, SCSI hard drive cabling, and system board functions. If your system uses a drive array controller, see the section for Drive Array Advanced Diagnostics (DAAD).
Table
SCSI Hard Drive Test Error Codes
Error Code
Description
SCSI Disk ID drive types test failed.
SCSI Disk Unconditional Format test failed. SCSI Disk Read Test Failed.
SCSI Disk SA/Media test failed. SCSI Disk Erase tape test failed. SCSI Disk Random Read test failed. Media load/unload test failed.
Recommended Action
1.Run the System Configuration Utility and verify the drive type.
2.Replace the SCSI disk drive signal and power cables and retest.
3.Replace the SCSI controller and retest.
4.Replace the SCSI disk drive and retest.
5.Replace the system board and retest.
SCSI/IDE CD-ROM Drive Test Error Codes
The 6600 series of Diagnostic error codes identifies failures with the
Table
SCSI/IDE CD-ROM Drive Test Error Codes
Error Code | Description | |
|
|
|
Recommended Action
1.Replace the
2.Check and/or replace the signal cable and retest.
3.Check the switch settings on the adapter board (if applicable).
4.Replace the SCSI controller (if applicable) and retest.
5.Replace the
6.Replace the system board and retest.
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater