3-24Diagnostic Tools

Serial Test Error Codes

The 1100 series of Diagnostic error codes identifies failures with serial/parallel interface board or system board functions.

Table 3-9

Serial Test Error Codes

Error Code

Description

Recommended Action

 

 

 

 

 

 

1101-xx

Serial port test failed.

1.

Check the switch settings on the

1109-xx

Clock register test failed.

 

 

Serial/Parallel Interface board (if applicable)

 

 

and retest.

 

 

 

 

 

 

 

 

2.

Replace the Serial/Parallel Interface board (if

 

 

 

 

 

applicable) and retest.

 

 

 

3.

Replace the system board and retest.

 

 

 

 

 

 

Modem Communications Test Error Codes

The 1200 series of Diagnostic error codes identifies failures with the modem(s).

Table 3-10

Modem Communications Test Error Codes

Error Code

Description

 

 

 

1201-xx Modem internal loopback test failed.

1202-xx Modem time-out test failed.

1203-xx Modem external termination test failed.

1204-xx Modem auto originate test failed.

1206-xx Dial multi-frequency tone test failed.

1210-xx Modem direct connect test failed.

Recommended Action

1.Refer to the modem documentation for correct setup procedures and retest.

2.Check the modem line and retest.

3.Replace the modem and retest.