Compaq 113803-001 manual Index-8, Fyi

Models: 113803-001

1 162
Download 162 pages 24.35 Kb
Page 154
Image 154

Index-8

error Continued

Drive Monitoring features are unobtainable, description 3-40

Drive Monitoring is NOT enabled for drive bay X, description 3-40

Drive time-out occurred on physical drive bay X,

description 3-40

 

Drive X indicates position Y, description

3-41

Duplicate write memory error, description

3-42

Error Detected On Boot Up 3-60

Error occurred reading RIS copy from drive (bay) X, description 3-42

FYI

Drive (bay) X is non-Compaq supplied, description 3-42

Identify controller data did not match with NVRAM, description 3-42

Identify logical drive data did not match with NVRAM, description 3-42

Insufficient adapter resources, description 3-42 Logical drive X failed due to cache error,

description 3-43

Logical Drive X status = FAILED, description 3-43

Logical Drive X status = INTERIM RECOVERY, description 3-43

Logical Drive X status = LOOSE CABLE DETECTED, description 3-43

Logical Drive X status = NEEDS RECOVER, description 3-43

Logical Drive X status = OVERHEATED, description 3-43

Logical Drive X status = OVERHEATING, description 3-43

Logical Drive X status = RECOVERING, description 3-43

Logical Drive X status = WRONG DRIVE REPLACED, description 3-44

Loose cable detected - logical drives may be marked FAILED until corrected, description 3-44

Mirror data miscompare, description 3-44 Mirrored memory location errors, description

3-44

NMI - Automatic Server Recovery Timer Expiration 3-61

NMI - Expansion Board Error 3-61

NMI - Expansion Bus Master Time-Out 3-61 NMI - Expansion Bus Slave Time-Out 3-61 NMI - Fail-Safe Timer Expiration 3-61 NMI - PCI Bus Parity Error 3-61

error Continued

NMI - Processor Parity Error 3-61

NMI - Software Generated Interrupt Detected Error 3-61

No configuration for Accelerator Board, description 3-44

NVRAM configuration present, controller not detected, description 3-38

Processor Exception 3-61

Processor Prefailure 3-60 Required System Fan Failure 3-61 SCSI port X, drive ID Y firmware needs

upgrading, description 3-44 Server Manager Failure 3-61

Set configuration command issued, description 3-44

Soft Firmware Upgrade required, description 3-44

Threshold for drive (bay) X violated, description 3-44

Threshold violations for drive (bay) X, description 3-45

Unknown disable code, description 3-45

UPS A/C Line Failure Shutdown or Battery Low 3-61

WARNING - Drive Write Cache is enabled on X, description 3-45

Warning bit detected, description 3-45 Wrong Accelerator, description 3-45

error codes See test error codes event format 3-48

event messages 3-48 events list See also IMD

defined 3-48 exploded view

chassis components 1-1 system components 1-2

external battery

installing replacement 2-43

installing replacement, illustrated 2-44 jumper location 4-6

jumper location, illustrated 4-6 part number 1-3

F

fan baffle

part number 1-4 removing 2-17 removing, illustrated 2-17 replacing 2-17

Page 154
Image 154
Compaq 113803-001 manual Index-8, Fyi