Power Supply
Table
Power Supply Specifications
|
| U.S. |
| Metric |
Input Specifications |
|
|
|
|
|
|
|
|
|
Nominal Line Voltage |
| 100 to 120 VAC |
| 200 to 240 VAC |
|
|
|
|
|
Range Input Line |
| 90 to 132 VAC |
| 180 to 270 VAC |
|
|
|
|
|
Frequency Range |
| 47 to 63 Hz |
| 47 to 63 Hz |
|
|
| ||
Power Factor | 0.95 | 0.95 | ||
|
|
|
|
|
Input Current |
| 8 A at 100 VAC |
| 6 A at 200 VAC |
|
|
|
|
|
Inrush Current |
| <150 A at 132 VAC (cold start) |
| <150 A at 132 VAC (cold start) |
|
|
|
|
|
Holdup Time |
| 20 ms from zero crossing at 120 VAC |
| 20 ms from zero crossing at 240 VAC |
|
|
|
|
|
General Specifications |
| To 104°F and 5,000 ft |
| To 40°C and 1,524 m |
|
|
|
|
|
Full Output Rating |
| To 90°F and 10,000 ft |
| To 32°C and 3,048 m (derate linearly) |
|
|
|
|
|
Minimum Load |
| 1.0 A on + 5 V output |
| 1.0 A on + 5 V output |
|
| 1.0 A on +12 V output |
| 1.0 A on +12 V output |
|
| 0.5 A on +3.3 V output |
| .5 A on +3.3 V output |
|
|
|
|
|
Ambient Temperature Range |
|
|
|
|
|
|
|
|
|
Operating |
| 50° to 104°F |
| 10° to 40°C |
|
|
|
|
|
Storage |
|
|
|
|
|
|
|
|
|
Dielectric Voltage Withstand |
|
|
|
|
|
|
|
|
|
Input to Output |
| 3000 VAC/min |
| 3000 VAC/min |
|
|
|
|
|
Input to Ground |
| 1500 VAC/min |
| 1500 VAC/min |
|
|
| ||
Common and Differential Mode |
| 2500V, 1 μs, damped sinusoid 600 V, 10 μs pulse 20% step change in AC input | ||
(superimposed on AC line) |
| voltage |
|
|
|
|
|
|
|
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater