5-3

Power Supply

Table 5-2

Power Supply Specifications

 

 

U.S.

 

Metric

Input Specifications

 

 

 

 

 

 

 

 

 

Nominal Line Voltage

 

100 to 120 VAC

 

200 to 240 VAC

 

 

 

 

 

Range Input Line

 

90 to 132 VAC

 

180 to 270 VAC

 

 

 

 

 

Frequency Range

 

47 to 63 Hz

 

47 to 63 Hz

 

 

 

Power Factor

0.95

0.95

 

 

 

 

 

Input Current

 

8 A at 100 VAC

 

6 A at 200 VAC

 

 

 

 

 

Inrush Current

 

<150 A at 132 VAC (cold start)

 

<150 A at 132 VAC (cold start)

 

 

 

 

 

Holdup Time

 

20 ms from zero crossing at 120 VAC

 

20 ms from zero crossing at 240 VAC

 

 

 

 

 

General Specifications

 

To 104°F and 5,000 ft

 

To 40°C and 1,524 m

 

 

 

 

 

Full Output Rating

 

To 90°F and 10,000 ft

 

To 32°C and 3,048 m (derate linearly)

 

 

 

 

 

Minimum Load

 

1.0 A on + 5 V output

 

1.0 A on + 5 V output

 

 

1.0 A on +12 V output

 

1.0 A on +12 V output

 

 

0.5 A on +3.3 V output

 

.5 A on +3.3 V output

 

 

 

 

 

Ambient Temperature Range

 

 

 

 

 

 

 

 

 

Operating

 

50° to 104°F

 

10° to 40°C

 

 

 

 

 

Storage

 

-40°to 149°F

 

-40°to 65°C

 

 

 

 

 

Dielectric Voltage Withstand

 

 

 

 

 

 

 

 

 

Input to Output

 

3000 VAC/min

 

3000 VAC/min

 

 

 

 

 

Input to Ground

 

1500 VAC/min

 

1500 VAC/min

 

 

 

Common and Differential Mode

 

2500V, 1 μs, damped sinusoid 600 V, 10 μs pulse 20% step change in AC input

(superimposed on AC line)

 

voltage

 

 

 

 

 

 

 

Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

Page 137