DAAD Diagnostic Messages Continued
Message
Drive (bay) X firmware needs upgrading
Drive (bay) X has invalid M&P stamp
Drive X indicates position Y
Description
Firmware on this physical drive is below the latest recommended version.
Physical drive has invalid monitor and performance data.
Message indicates which physical drive appears to be scrambled or in a drive bay other than the one for which it was originally configured.
Recommended Action
Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision.
Run the System Configuration Utility to properly initialize this drive.
Examine the graphical drive representation on DAAD to determine proper drive locations. Remove drive X and place it in drive position Y. Rearrange the drives according to the DAAD instructions.
Drive (bay) X RIS copy mismatch
Drive (bay) X upload code not readable
Drive (bay) X has loose cable
The copies of the RIS on this drive do not match.
An error occurred while DAAD was trying to read the upload code information from this drive.
The array controller could not communicate with this drive at power- up. This drive has not previously failed.
This drive may need to be replaced. Check for other errors.
If there were multiple errors, this drive may need to be replaced.
Check all cable connections first. The cables could be bad, loose, or disconnected. Turn on the system and attempt to reconnect signal/power cable to the drive. If this does not work, replace the cable. If that does not work, the drive may need to be replaced.
Drive (bay) X is a replacement drive
Drive (bay) X is a replacement drive marked OK
This drive has been replaced. This message displays if a drive is replaced in a fault tolerant logical volume.
This drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure (for example, if a drive has previously failed, then when DAAD is run, the drive starts working again).
If the replacement was intentional, allow the drive to rebuild.
Replace the drive.
Drive (bay) X is | The indicated physical drive has failed. | Replace this drive. |
failed |
|
|
|
|
|
Drive (bay) X has | Drive has insufficient capacity to be | Replace this drive with a larger capacity drive. |
insufficient | used in this logical drive configuration. |
|
capacity for its |
|
|
configuration |
|
|
|
|
|
Drive (bay) X is | This drive is being rebuilt from the | Normal operations should occur. |
undergoing drive | corresponding mirror or parity data. |
|
recovery |
|
|
Continued
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater