DAAD Diagnostic Messages Continued

3-41

Message

Drive (bay) X firmware needs upgrading

Drive (bay) X has invalid M&P stamp

Drive X indicates position Y

Description

Firmware on this physical drive is below the latest recommended version.

Physical drive has invalid monitor and performance data.

Message indicates which physical drive appears to be scrambled or in a drive bay other than the one for which it was originally configured.

Recommended Action

Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision.

Run the System Configuration Utility to properly initialize this drive.

Examine the graphical drive representation on DAAD to determine proper drive locations. Remove drive X and place it in drive position Y. Rearrange the drives according to the DAAD instructions.

Drive (bay) X RIS copy mismatch

Drive (bay) X upload code not readable

Drive (bay) X has loose cable

The copies of the RIS on this drive do not match.

An error occurred while DAAD was trying to read the upload code information from this drive.

The array controller could not communicate with this drive at power- up. This drive has not previously failed.

This drive may need to be replaced. Check for other errors.

If there were multiple errors, this drive may need to be replaced.

Check all cable connections first. The cables could be bad, loose, or disconnected. Turn on the system and attempt to reconnect signal/power cable to the drive. If this does not work, replace the cable. If that does not work, the drive may need to be replaced.

Drive (bay) X is a replacement drive

Drive (bay) X is a replacement drive marked OK

This drive has been replaced. This message displays if a drive is replaced in a fault tolerant logical volume.

This drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure (for example, if a drive has previously failed, then when DAAD is run, the drive starts working again).

If the replacement was intentional, allow the drive to rebuild.

Replace the drive.

Drive (bay) X is

The indicated physical drive has failed.

Replace this drive.

failed

 

 

 

 

 

Drive (bay) X has

Drive has insufficient capacity to be

Replace this drive with a larger capacity drive.

insufficient

used in this logical drive configuration.

 

capacity for its

 

 

configuration

 

 

 

 

 

Drive (bay) X is

This drive is being rebuilt from the

Normal operations should occur.

undergoing drive

corresponding mirror or parity data.

 

recovery

 

 

Continued

Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

Page 98
Image 98
Compaq 113803-001 Drive bay X has invalid M&P stamp, Physical drive has invalid monitor and performance data, Insufficient