DAAD Diagnostic Messages Continued
Message
Drive (bay) X was inadvertently replaced
Duplicate write memory error
Description
The physical drive was incorrectly replaced after another drive failed.
Data could not be written to the array accelerator board in duplicate due to the detection of parity errors. This is not a data loss situation.
Recommended Action
Replace the drive that was incorrectly replaced and replace the original drive that failed. Do not run the System Configuration Utility and try to reconfigure; data will be lost.
Replace the array accelerator board.
Error occurred reading RIS copy from drive (bay) X
FYI: Drive (bay) X is
Identify controller data did not match with
NVRAM
An error occurred while DAAD was trying to read the RIS from this drive.
The installed drive was not supplied by Compaq.
The identify controller data from the array controller did not match the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. It could also occur if the firmware on the controller has been upgraded and the System Configuration Utility was not run.
If there were multiple errors, this drive may need to be replaced.
If problems exist with this drive, replace it with a Compaq drive.
Check the identify controller data under the Inspect Utility. If the firmware version field is the only thing different between the controller and nonvolatile RAM data, this is not a problem. Otherwise, run the System Configuration Utility.
Identify logical | The identify unit data from the array |
drive data did not | controller did not match with the |
match with | information stored in nonvolatile RAM. |
NVRAM | This could occur if new, previously |
| configured drives have been placed in a |
| system that has also been previously |
| configured. |
|
|
Run the System Configuration Utility to configure the controller and nonvolatile RAM.
Insufficient | The adapter does not have sufficient |
adapter resources | resources to perform operations to the |
| array accelerator board. Drive rebuild |
| may be occurring. |
|
|
Operate the system without the array accelerator board until the drive rebuild completes.
Continued