12
INSTALLATION
Optional Mantel Installation (Cont.)
Installing Blower Accessory GA3450T in
INSTALLATION
Continued
10. Attach wood base to floor with two 1 3/4" black screws pro- vided (see Figure 13). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 17).
11. Install gas line. See Connecting To Gas Supply, pages 17 and 18.
12. Check for leaks. See Checking Gas Connections, page 19.
13. Place mantel around fireplace. Be careful not to damage wall or mantel.
14. Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 12, page 11).
15. Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the brass louvers (see Figure 12, page 11).
16. Reinstall top brass louvers.
1 3/4" Screw
Wood Base
Figure 13 - Attaching Wood Base to Floor
Assembling Brass Trim (Brass trim shipped with mantel)
1.Remove packaging from three remaining pieces of brass trim.
2.Locate two adjusting plates with set screws, and two shims in the hardware packet.
3.Align shim under adjusting plate as shown in Figure 14.
4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).
5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 14).
6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
7.Repeat steps 1 through 6 for other corner.
8.Set brass assembly aside for later installation.
Set
Screws
Adjusting | Top Brass Trim |
Plate | Slot |
| Mitered Edge |
Shim |
|
Side Brass Trim
Figure 14 - Assembling Brass Trim
INSTALLING OPTIONAL BLOWER ACCESSORY GA3450T IN
Removing Upper Louver Assembly and Branch Support
To install the blower accessory, you must first remove the upper louver assembly.
1.Lift screen off fireplace and remove log set if installed.
2.Remove 2 screws from each side of branch support and pull branch support out (see Figure 15).
3.Remove 4
4.Pull upper louver assembly straight out from the cabinet. Be care- ful not to scratch the paint. Set louver assembly and screws aside.
5.Open lower louver door by swinging door down (see Figure 16, page 13).
Blower Bracket
Mounting Holes
Upper Louver
Assembly
Branch Support
Figure 15 - Removing Upper Louver Assembly and Branch Support
Installing Blower Accessory
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
CAUTION: Verify proper operation after servicing.
Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is
1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.
2.Make sure the wire harness is firmly connected to the termi- nals on the blower bracket assembly.