Desa EFS10TP, EFS26NR, FMH26PR, EFS10TN Troubleshooting, Observed Problem, Possible Cause, Remedy

Models: FMH26PR EFS10TN EFS10TP FMH26NR EFS26NR

1 44
Download 44 pages 38.64 Kb
Page 29
Image 29
TROUBLESHOOTING

TROUBLESHOOTING

29

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

 

spark at ODS/pilot

 

tor cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

 

5.

Ignitor electrode positioned wrong

5.

Replace pilot assembly

 

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

 

PILOT position

 

position

 

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

 

removed

 

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

Maintenance, page 28) or replace ODS/

 

 

 

 

 

pilot assembly

 

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

 

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

 

knob pressed in 30 seconds

 

 

3.

Safety interlock system has been

3.

Wait one minute for safety interlock sys-

 

 

 

triggered

 

tem to reset. Repeat ignition operation

 

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

 

5.

Pilot flame not touching thermocouple,

5.

A) Contact local natural or propane/LP

 

 

 

which allows thermocouple to cool,

 

gas company

 

 

 

causing pilot flame to go out. This prob-

 

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

the following:

 

Maintenance, page 28) or replace ODS/

 

 

 

A) Low gas pressure

 

pilot assembly

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

 

6.

Thermocouple connection loose at con-

6.

Hand tighten until snug, then tighten

 

 

 

trol valve

 

1/4 turn more

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

 

8.

Control valve damaged

8.

Replace control valve

REMEDYFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107032-01E

Page 29
Image 29
Desa EFS10TP, EFS26NR, FMH26PR, EFS10TN, FMH26NR installation manual Troubleshooting, Observed Problem, Possible Cause, Remedy