14

INSTALLATION

Installing Blower Accessory GA3450T in Remote-Ready Models (Cont.) Installing Blower Accessory GA3450T in Thermostat-Controlled Models

INSTALLATION

Continued

3.A licensed electrician must follow the wiring diagram to con- nect incoming electrical supply to fan kit wiring harness (see Figure 19).

4.Plug power cord to the outlet receptacle (not provided) as shown in Figure 20. Wind the extra cable in power cord and and tie it up with the plastic wire strap (see Figure 20). Set the cable bundle between the burner bracket and outer casing, away from the burner.

5.Test to make sure the blower is working properly.

6.Reinstall upper louver assembly (see Figure 15, page 12) and close lower louver.

 

Fan Switch

 

 

 

 

 

 

 

(Auto/Off/On)

 

 

 

 

 

 

 

 

1 Auto

 

 

 

 

 

 

 

Off

2

 

 

 

 

 

 

 

 

 

 

 

3

Blue

 

Thermostat

 

 

 

On

 

 

 

Switch

 

 

 

 

 

 

(N.O.)

110/115

 

 

Red

 

 

 

 

Blue

V.A.C.

 

 

 

 

Blower

 

Black

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

 

 

White

 

 

 

 

 

 

White

 

 

Green

 

 

 

 

 

 

Green

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

INSTALLING OPTIONAL BLOWER ACCESSORY GA3450T IN THERMOSTAT- CONTROLLED MODELS

Removing Upper Louver Assembly

To install the blower accessory, you must first remove the upper louver assembly.

1.Remove 4 screws from upper louver assembly (see Figure 21). Save these screws.

2.Pull upper louver assembly straight out from the cabinet. Be care- ful not to scratch the paint. Set louver assembly and screws aside.

Figure 19 - Wiring Diagram For Blower Accessory Built-In Installation

Blower Bracket

 

Assembly

Wire Harness

Screw

Switch

Power

Outlet Receptacle

Cord

 

(Not Supplied)

 

 

Blower Bracket

Mounting Holes

Brass

Screws

Upper Louver Assembly

Switch

Plate Blue

Black

Red

Plastic

 

 

Wire Strap

Wire Harness

Clamp Connector

 

 

(not included)

 

Lower Louver Door

Figure 20 - Installing Blower Bracket Assembly

Figure 21 - Removing Upper Louver Assembly

For..com

107032-01E

Page 14
Image 14
Desa EFS10TP, EFS26NR, FMH26PR, EFS10TN, FMH26NR installation manual Extension Cord, Removing Upper Louver Assembly