OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

INSTALLATION

Optional Wireless Hand-Held Remote Control Accessories [Remote-Ready Models Only] (Cont.) Optional Wall Mounted Thermostat - GWMT1 [Remote-Ready Models Only]

21

INSTALLATION

Continued

Remote

Receiver

(Remote-Ready Models Only)Red Wire

Black Wire Manual background

Wire Harness* Manual background

Wires from

Valve

Red Wire

Black Wire

Figure 38 - Installing Remote Receiver

* Wire harness provided in the fireplace hardware pack.

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery (not included). Place bat- tery into the battery housing.

3.Replace battery cover onto remote control unit.

Terminal

Battery Cover

Remote

Wires

Control Unit

9-Volt

 

Battery

 

Manual background Battery

Housing

Figure 39 - Installing Battery in Hand-Held Remote Control Unit (GHRC Series)

Terminal Wires

9-Volt

Remote

Battery

Control Unit

 

Battery

Battery Cover

 

Housing

 

Figure 40 - Installing Battery in Hand-Held Remote Control Unit (GHRCTA Series)

OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

(Remote-Ready Models Only)

Manual background WARNING: Read and follow installation instruc- tions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

Manual background WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Connect one terminal of 25 ft. wire to bottom contact of switch (see Figure 41).

2.Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the posi- tions on your unit as pictured in Figure 41. If wires are not “crossed” the thermostat will not work.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a loca- tion where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.

4.Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

5.Feed the electrical wires through the rectangular slots on each side of the base (see Figure 42, page 22).

Manual background WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Switch on Gas

 

 

Fireplace

Control

 

 

 

 

Valve

 

AUTO

 

 

O

 

 

FF

 

 

ON

To Wall

 

One

 

Thermostat

To Wall

terminal

or Switch

Thermostat

of 25 ft.

 

or Switch

wire

 

 

Figure 41 - Connecting Wire Terminals