Hard Drive Test Error Codes
The 1700 series of Diagnostic error codes identifies failures with hard drives, hard drive controller boards, hard drive cabling, and system board functions. If your system uses a drive array controller, see the section for Drive Array Advanced Diagnostics (DAAD).
Table
Hard Drive Test Error Codes
Error Code | Description | |
|
|
|
Fixed disk ID drive types test failed. | ||
Fixed disk format test failed. | ||
Fixed disk read test failed. | ||
Fixed disk write/read/compare test failed. | ||
Fixed disk random seek test failed. | ||
Fixed disk controller test failed. | ||
Fixed disk format bad track test failed. | ||
Fixed disk reset controller test failed. | ||
Fixed disk park head test failed. | ||
Fixed disk head select test failed. | ||
Fixed disk conditional format test failed. | ||
Fixed disk ECC* test failed. | ||
Fixed disk drive power mode test failed. | ||
Drive Monitoring failed. | ||
Invalid fixed disk drive type failed. | ||
|
|
|
* Error Checking and Correcting
Recommended Action
1.Run the System Configuration Utility and verify the drive type.
2.Replace the fixed disk drive signal and power cables and retest.
3.Replace the fixed disk drive controller and retest.
4.Replace the fixed disk drive and retest.
5.Replace the system board and retest.
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater