3-8Diagnostic Tools

POST Error Messages Continued

 

 

Audible Beeps

 

 

Error Code

 

L=Long S=Short

 

Probable Source of Problem

703-CMOS reports a

 

2S

 

Coprocessor or configuration

coprocessor that has

 

 

 

error.

not been detected

 

 

 

 

 

 

 

 

 

1151-Com Port 1

 

2S

 

Both external and internal serial

Address Assignment

 

 

 

ports are assigned to COM1.

Conflict

 

 

 

 

 

 

 

 

 

1152-Com Port 2, 3,

 

2S

 

Both external and internal serial

or 4 Address

 

 

 

ports are assigned to COM2,

Assignment Conflict

 

 

 

COM3 or COM4.

 

 

 

 

 

1600-Server

 

None

 

Server Manager/R board failure.

Manager/R Failure

 

 

 

Error code displays after error

 

 

 

 

message.

 

 

 

 

 

1610-Temperature

 

2S

 

Ambient system temperature

violation detected.

 

 

 

too hot.

Waiting for system to

 

 

 

 

cool

 

 

 

 

 

 

 

 

 

Recommended Action

1.Run the System Configuration Utility and correct.

2.Replace the coprocessor.

Run the System Configuration Utility and correct.

Run the System Configuration Utility and correct.

Run Diagnostics. Replace failed assembly as indicated.

Check fan in system environment.

1611-Fan [fan

2S

Required fan has failed.

Check fans.

description] failure

 

 

 

detected

 

 

 

 

 

 

 

1611-Fan [fan

2S

Fan not present.

Make sure fans are plugged in.

description] not

 

 

 

present

 

 

 

 

 

 

 

1612-Primary power

2S

Primary power supply has

supply failure

 

failed.

 

 

 

1613-Low System

None

Real time clock system battery

Battery

 

is running low on power.

 

 

 

1615-Power Supply

None

A power supply has failed.

Failure in Bay X

 

 

 

 

 

1616-Power Supply

2L, 2S

Single power supply system is

Configuration Error

 

installed in Bay 2 and not in

 

 

Bay 1.

 

 

 

1701-SCSI Controller

None

A test on the Fast SCSI-2

failure

 

Controller failed

Replace power supply as soon as possible.

Run Diagnostics. Replace failed assembly as indicated.

Replace or check specified power supply.

Move power supply from Bay 2 to Bay 1.

Run Diagnostics. Replace failed assembly as indicated.