Diskette Drive Test Error Codes
The 600 series of Diagnostic error codes identifies failures with diskette, diskette drive, or system board functions.
Table
Diskette Drive Test Error Codes
Error Code | Description | |
|
|
|
Diskette ID drive types test failed. | ||
Diskette format failed. | ||
Diskette read test failed. | ||
Diskette write/read/compute test failed. | ||
Diskette random seek test failed. | ||
Diskette ID media failed. | ||
Diskette speed test failed. | ||
Diskette wrap test failed. | ||
Diskette write protect test failed. | ||
Diskette reset controller test failed. | ||
Diskette change line test failed. | ||
Pin 34 is not cut on 360 KB diskette drive. | ||
Diskette type error. | ||
Diskette drive speed not within limits. | ||
Diskette drive/media ID error. | ||
|
|
|
Recommended Action
1.Replace the diskette and retest.
2.Check and/or replace the diskette power and signal cables and retest.
3.Replace the diskette drive and retest.
4.Replace the system board and retest.
1.Replace the media and retest.
2.Run the Configuration utility and retest.
Monochrome Video Board Test Error Codes
The 800 series of Diagnostic error codes identifies failures with monochrome video boards or system board functions.
Table
Monochrome Video Board Test Error Codes
Error Code | Description | Recommended Action | |||
|
|
|
|
|
|
Video memory test failed. | 1. | Replace monitor and retest. | |||
Monochrome video text mode test failed. | 2. | Replace the Advanced VGA board and retest. | |||
|
|
| 3. | Replace monochrome board and retest. | |
|
|
| 4. | Replace the system board and retest. | |
|
|
|
|
|
|
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater