DAAD Diagnostic Messages Continued
Message |
| Description |
| Recommended Action |
Accelerator | Cache board was probably replaced with |
status: Cache was | one of a different size. |
automatically |
|
configured during |
|
last controller |
|
reset. This can |
|
occur when |
|
cacheboard is |
|
replaced with one |
|
of a different size. |
|
|
|
Nothing needs to be done. Normal operations should continue.
Accelerator status: Valid data found at reset
Accelerator status: Warranty alert
Valid data was found in posted write memory at reinitialization. Data will be flushed to disk.
Catastrophic problem with array accelerator board. Refer to other messages on Diagnostics screen for exact meaning of this message.
Not an error or data loss condition. No action needs to be taken.
Replace the array accelerator board.
Adapter/NVRAM ID mismatch
EISA nonvolatile RAM has an ID for a | Run the System Configuration Utility. |
different controller from the one physically |
|
present in the slot. |
|
|
|
Battery X not fully charged
Board not attached
Battery is not fully charged.
Array controller configured for use with array accelerator board, but one is not attached.
Allow 36 hours to recharge them.
Attach array accelerator board to array controller.
NVRAM configuration present, controller not detected
EISA nonvolatile RAM has a configuration for an array controller but there is no board in this slot. Either a board has been removed from the system or a board has been placed in the wrong slot.
Place the array controller in the proper slot or run the System Configuration Utility to reconfigure nonvolatile RAM to reflect the removal or new position.
Compatibility port problem detected
Compatibility port configured for this IDA | A hardware problem has occurred; replace the IDA |
controller. When DAAD was verifying this | controller. |
interface, a serious problem was detected. |
|
|
|