Keyboard Test Error Codes
The 300 series of Diagnostic error codes identifies failures with keyboard and system board functions.
Table
Keyboard Test Error Codes
Error Code
Description
Keyboard short test, 8042
Keyboard LED test, 8042
Recommended Action
The following steps apply to error codes 301-xx through 304-xx:
1.Check the keyboard connection. If disconnected, turn off the computer and connect the keyboard and retest.
2.Replace the keyboard and retest.
3.Replace the system board and retest.
Parallel Printer Test Error Codes
The 400 series of Diagnostic error codes identifies failures with parallel printer interface card or system board functions.
Error Code
Table
Parallel Printer Test Error Codes
Description | Recommended Action | |||
|
|
|
| |
Printer failed or not connected. | The following steps apply to error codes | |||
Printer data register failed. | through | |||
|
|
| ||
Printer pattern test failed. | 1. | Connect the printer and retest. | ||
|
|
| ||
Printer failed or not connected. | 2. | Check the power to the printer and retest. | ||
|
|
| ||
|
| 3. | Install the loopback connector and retest. | |
|
| 4. | Check the switch on the Serial/Parallel Interface | |
|
|
|
| board (if applicable) and retest. |
|
| 5. | Replace the Serial/Parallel Interface board (if | |
|
|
|
| applicable) and retest. |
|
| 6. | Replace the system board and retest. | |
|
|
|
|
|
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater