DAAD Diagnostic Messages Continued

3-43

Message

Logical drive X failed due to cache error

Logical Drive X status = FAILED

Description

This logical drive failed due to a catastrophic cache error.

This status could be issued for several reasons. If this logical drive is configured for No Fault Tolerance and one or more drives fail, this status will occur. If mirroring is enabled, and any two mirrored drives fail, this status will occur. If Data Guarding is enabled, and two or more drives fail in this unit, this status will occur. This status may also occur if another configured logical drive is in the WRONG DRIVE REPLACED or LOOSE CABLE DETECTED state.

Recommended Action

Replace the array accelerator board and reconfigure using the System Configuration Utility.

Check for drive failures, wrong drive replaced, or loose cable messages. If there was a drive failure, replace the failed drive(s) and then restore the data for this logical drive from the tape backup. Otherwise, follow the wrong drive replaced or loose cable detected procedures.

Logical Drive X status = INTERIM RECOVERY

A physical drive in this logical drive has

Replace the failed drive as soon as possible.

failed. The logical drive is operating in

 

interim recovery mode and is

 

vulnerable.

 

 

 

Logical Drive X status = LOOSE CABLE DETECTED

Logical Drive X status = NEEDS RECOVER

A physical drive has a cabling problem.

A physical drive in this logical drive has failed and has now been replaced. This drive needs to be rebuilt from the mirror drive or the parity data.

Turn the system off and attempt to reattach the cable onto the drive. If this does not work, replace the cable.

When booting up the system, select the "F1 - rebuild drive" option to rebuild the replaced drive.

Logical Drive X status =

OVERHEATED

Logical Drive X status =

OVERHEATING

Logical Drive X status =

RECOVERING

The temperature of the Intelligent Array

Check the fans and the operating environment.

Expansion System drives is beyond safe

 

operating levels and it has shut down to

 

avoid damage.

 

 

 

The temperature of the Intelligent Array

Check the fans and the operating environment.

Expansion System drives is beyond safe

 

operating levels.

 

 

 

A physical drive in this logical drive has

Nothing needs to be done. Normal operations can

failed and has now been replaced. The

occur.

replaced drive is rebuilding from the mirror drive or the parity data.

Continued

Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide

Page 100
Image 100
Compaq 113803-001 Replace the failed drive as soon as possible, Interim recovery mode and is Vulnerable, Avoid damage