Step 9 Connect the ground, positive, and negative leads to the power source.
Step 10 Turn the branch source breaker on.
Step 11 Turn the power supply switch to the On (I) position.
Step 12 Verify that the LEDs illuminate.
This completes the procedure for connecting DC-input power.
Verifying Power Supply operation

Follow this procedure to verify power supply is operating correctly.

Step 1 Check that the power supply LEDs are:
INPUT OK is green
FAN OK is green
OUTPUT FAILED is not illuminated
Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco
ASR1002 router.
MCP_SCAL_R1#sho env all
Chassis type: ASR1002
The following output displays:
If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for
assistance or additional instructions.
Start the Cisco ASR 1002 Router
After installing your Cisco ASR 1002 Router and connecting cables, start the router as follows.
Check the following conditions before you start the Cisco ASR 1002 Router:
The Cisco ASR 1002 Router has one slot for FP0 with three subslots for SPAs, subslots 1, 2, and 3. Make certain that each
shared port adapter is firmly seated in its subslot and its captive screws are securely tightened.
The Cisco ASR1000-ESP5 or ASR1000-ESP10 forwarding processor in the Cisco ASR 1002 router is inserted in slot F0, is
firmly seated in its slot, and its captive screws are securely tightened.
All network interface cables are connected.
The console terminal is turned on.
Slot Type State Insert Time
R0 ASR1000-RP1 ok,active 00:03:19
F0 ASR1000-ESP10 ok,active 00:03:19
P0 ASR1002-PWR-AC ok 00:02:50
P1 ASR1002-PWR-AC ps, fail 00:02:50
Slot CPLD Version Firmware Version
R0 08060301 12.2(0:0)
F0 08041102 12.2(33r)XN2