POST Error Messages Continued
|
| Audible Beeps |
|
|
Error Code |
| L=Long S=Short |
| Probable Source of Problem |
|
| None |
| Cable or hard drive failure. |
Responding, Physical |
|
|
|
|
Drive |
|
|
|
|
Check cables or |
|
|
|
|
replace physical |
|
|
|
|
drive X. |
|
|
|
|
Select "F1" to |
|
|
|
|
continue - drive array |
|
|
|
|
will remain disabled. |
|
|
|
|
Select "F2" to fail |
|
|
|
|
drive(s) that are not |
|
|
|
|
responding - |
|
|
|
|
Interim Recovery |
|
|
|
|
Mode will be enabled |
|
|
|
|
if configured for fault |
|
|
|
|
tolerance. |
|
|
|
|
|
|
|
|
|
|
| None |
| Hard drive error or wrong drive |
Configuration Error |
|
|
| type. |
|
|
|
|
|
|
| None |
| Hard drive error or wrong drive |
|
|
|
| type. |
|
|
|
|
|
| None |
| This indicates that while the | |
Reports Valid Data |
|
|
| system was in use, power was |
Found in Array |
|
|
| interrupted while data was in |
Accelerator. |
|
|
| the Array Accelerator memory. |
Data will automatically |
|
|
| Power was then restored |
|
|
| within eight to ten days, and | |
be written to drive |
|
|
| |
|
|
| the data in the Array | |
array. |
|
|
| |
|
|
| Accelerator was flushed to the | |
|
|
|
| |
|
|
|
| drive array. |
|
|
|
|
|
Recommended Action
1.Check the cable connections.
2.Replace the cables.
3.Replace the drive.
4.If you do not want to replace the drives now, press F2.
Run the System Configuration Utility and Diagnostics and correct.
Run the System Configuration Utility and Diagnostics and correct.
No action necessary; no data has been lost. Perform orderly system shutdowns to avoid data remaining in the Array Accelerator.
Continued