DAAD Diagnostic Messages Continued
Message
Controller needs replacing (DAAD Error 104)
Controller reported POST error.
Error Code: x
Controller restarted with a signature of zero
Description
The Intelligent Array Expansion System firmware is less than version 1.14.
The controller returned an error from its internal
DAAD did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller.
Recommended Action
Replace the controller as soon as possible.
Replace the controller.
Run the System Configuration Utility to configure the controller and nonvolatile RAM.
DAAD recorded errors attempting to access: X
Disable command issued
DAAD found errors while attempting to access physical drive X, believed to be operational. Message followed by specific information about the error.
Replace the drive, or correct the condition that caused the error.
Restart the system. Run the System Configuration Utility to reinitialize the array accelerator board.
Drive (bay) X needs replacing (DAAD Error 102)
Drive Monitoring features are unobtainable
The
DAAD unable to get monitor and performance data due to fatal command problem such as drive time- out, or unable to get data due to these features not supported on the controller.
Replace the drive.
Check for other errors
Drive Monitoring is NOT enabled for drive bay X
Drive
The monitor and performance features have not been enabled.
DAAD issued a command to a physical drive and the command was never acknowledged.
Run the System Configuration Utility to initialize the monitor and performance features.
The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution.