HOW YOUR WATER SOFTENER WORKS
SECTION 2
11
2A. FACE PLATE TIMER FEATURES
OPTIONAL SETTINGS– CLEAN FEATURE
MINUTES, MAXIMUM DAYS BETWEEN REGEN-
ERATIONS, and 12 / 24 HOUR TIME READINGS:
1. Toset 1, 2 or all 3 options, press and hold SELECT
for 3 seconds. Then press again until the CLEAN
TIME display shows.
CLEAN TIME
MIN
CLEAN TIME
MIN
default minutes example: time set to 3minutes
CLEAN feature minutes: If you are using this
feature (page 7), the length of the extra backwash
cycle automatically sets to 7 minutes. However,you
canadjust this time from 1 to 15 minutes in length. To
changethis cycle time, use the UP button to increase
the time, or the DOWN button to shorten the time. If
no change is desired, continue below.
2. Press SELECT again to show the following
RECHARGE display.
RECHARGE
DAY
default display example: set to 4 days maxi-
mum between regenerations
RECHARGE
DAY
Maximum days between regenerations: The
faceplate timer automatically controls regeneration
frequency (see page 14). This provides the greatest
operating efficiency, and normally the maximum
daysfeatur e is not needed. If you want to be certain
a regeneration will occur within a number of days,
use this feature. For example, if your water supply
contains iron and you want the softener to
regenerate at least once every few days to keep the
resin bed clean, set the display as typically shown
above. Setting is available from 1 to 15 days by using
the UP and DOWN buttons.

3. Press SELECT to show the 12 HOUR display.

12 or 24 hour clock: All
time displays are shown in
standard clock time (1 to 12 PM;
and 1 to 12 AM) at the 12 hr
default setting. If military time
displays are desired, set to 24 hr
by pressing the UP button.

4.Press SELECT to retur n the present time display.

WATER FLOW THROUGH THE SOFTENER

If soft water is in use, the water
flow bars continually scroll
across the display. The bars
scroll slowly when water flow is
slow, and move faster as water
flow increases. The flow bars do
not show when all faucets and
water using appliances are off.

RECHARGE TIME REMAINING and VALVE

POSITION INDICATORS

Oneof the valve position indicaĆ
tors (Serv, Fill, Brine, Bkwsh,
Rinse) is displayed while the
softener is recharging (See
*NOTE onpage 10 if the CLEAN
feature is ON). RECHARGE
flashesin the display and, beginĆ
ning with Brine, the minutes of recharge remaining
before return to service appears in place of the
present time. When the valve is moving from one
cycle to another, both position indicators are
flashing.

PROGRAM MEMORY

If electrical power to the softener goes off, the time
display is blank but the face plate timer keeps the
correct time for about 6 hours. When electrical
powercomes on again, you have to reset the present
time only if the display is flashing. The HARDNESS
andRECHARGE TIME never requir e resetting unless
a change is desired.
Even if the timer is incorrect after a long power
outage, the softener works as it should to keep your
water soft. However,regenerations may occur at the
wrong time of day until you reset the timer to the
correct time of day.

ERROR CODE

An error code could appear in
the face plate display if a probĆ
lem occurs in the softener elecĆ
tronics. If you see an error code
instead of the present time of
day, please call you local Sears
Service Department for service.
TIME
AM
PM
TIME
PM
WATER FLOW
OFF
8
7
6
5
4
3
2
1
PM
WATER FLOW
OFF
8
7
6
5
4
3
2
1
no water flow
Flow bars scroll when
soft water is in use.
OFF
8
7
6
5
4
3
2
1
Serv
Fill
Brine
Bkwsh
Rinse
MIN
RECHARGE
TIME REMAINING
valve
position
indicators
recharge
time