Configuration

Sub-Menus

Configure Inv/Chg Menu

Cfg/Inv Chg is a sub-menu. If selected, the following list of sub-menu items appears.

Max Chg Rate

Full name Maximum charge rate

Configurable setting The actual battery charge rate is determined by two things: the battery bank size setting (C) divided by 5 (C÷5) and the charge rate setting (0 to 100%).

For example, if the battery bank size is set to 300 Ah (C) and the charge rate is set at 100%, the maximum charge rate is:

300 ÷ 5 = 60 amps × 100% which is a 60 amp charge rate.

If the charge rate setting is adjusted to 50%, the maximum charge rate is: 300 ÷ 5 = 60 amps × 50% which is a 30 amp charge rate.

The Freedom SW 3000 has a maximum charge rate of 150 amps. Even though you can set a bank size of 2000 Ah, where C÷5 is 2000 ÷5 = 400 amps, the Freedom SW 3000 would still charge at 150 amp maximum.

Max Chg Rate

[100%]

You can adjust the Max Chg Rate settings as follows:

Range of values

Increment

Default

 

 

 

10% to 100%

10

100%

 

 

 

When to use Displayed only if in charger mode when you wish to control the maximum charge rate to your batteries.

Lo DC Volt

Full name Low DC input voltage shutdown

Configurable setting This setting lets you set the low voltage shutdown level for the inverter.

Lo DC Volt

[10.0V]

You can adjust the Lo DC Volt settings as follows:

Range

Increment

Default

 

 

 

10 to 12 volts

0.1 volt

10 volts

 

 

 

When to use This setting limits the depth of discharge on your battery.

Batt Type

This feature is the same as described on the basic menu on page 37.

Batt Size

This feature is the same as described on the basic menu on page 37.