Configuration

Batt Type

Full name Battery Type

Configurable setting Select the type of battery from flooded, custom, AGM, or gel. If a battery temperature sensor is not present, the Freedom SW 3000 uses the hot setting which is the default value, unless the setting has been adjusted during configuration.

Batt Type

[Flooded]

When to use This setting is adjusted for the type of battery you have. It is important during installation to choose the correct setting (battery type) to optimize the charge algorithm for your battery and to properly enable or disable equalization. See “Battery Charging Reference” on page 55.

The custom setting is selected to get the battery settings programmed by the dealer.

Batt Size

Full name Battery size

Configurable setting This features let you select the size of the battery bank being charged.

Batt Size

[440 Ah]

You can adjust the Battery Size settings as follows:

Range of values

Increment

Default

50 Ah to 2000 Ah

10 Ah

440 Ah

When to use Adjust this setting to your actual battery bank size.

Outcome Reduces the maximum charger current to protect against charging smaller batteries too aggressively. This setting charges batteries appropriately based on capacity. (See the Battery Information section in the FSW3000 Sine Wave Inverter/Charger Installation Guide for more information.)

Clear Faults

Purpose Clear Faults is a command which clears all active faults in the Freedom SW 3000. When faults are cleared, the device will resume normal operation. If the fault condition still exists, the fault will reoccur. See “Fault Types” on page 45 for an explanation of faults.

Clear Faults

You can adjust the Clear Faults settings as follows:

Value

Effect

 

 

Yes

Faults are cleared

 

 

No

No action

 

 

975-0545-01-01

37

Page 51
Image 51
Xantrex Technology SW 3000 user service Batt Type, Batt Size, Clear Faults, Range of values Increment Default, Value