GE AES23, AES15, AES18, AED18 installation instructions Opemting Your Air Conditioner Controb

Page 4

Opemting Your Air Conditioner Controb(continued)

For normal cooling

1.Set the Selector Switch at HIGH COOL.

2.Set the Thermostat Control at the desired number (usually 5-7 is a good starting position). If room temperature is not satisfactory after a reasonable time, set the Thermostat Control at a higher number for a cooler room or at a lower number for a warmer room.

3.Set the Energy Saver Switch* at NORMAL position for continuous fan operation or at SAVE position to automatically cycle the fan on and off with the compressor.

4.Set the Ventilation Control at CLOSED except for brief periods when you want to exhaust room air to the outside.

For maximum cooling

1.Set the Selector Switch at HIGH COOL.

2.Turn the Thermostat Control to 10.

3.Set the Ventilation Control at

CLOSED.

4.Set the Energy Saver Switch* at the NORMAL position.

For quieter operation

1.Set the Selector Switch at LOW COOL position.

2.Turn the Thermostat Control to the desired number.

When the Thermostat Control is set on 9 or 10 and the Fan is set on low speed, moisture may freeze on the coils and prevent the unit from cooling. If this happens, set the Fan at high speed and set the Thermostat Control to a lower number.

3.Set the Ventilation Control at

CLOSED.

4.Set the Energy Saver Switch* at the NORMAL position.

Note: When the Energy Saver Switch* is at the SAVE position, changes in the sound level may be more noticeable than when it’s at the NORMAL position.

For nighttime operation

During the cooler evening hours, we recommend that you set the Selector Switch at LOW COOL for very quiet operation and the Thermostat Control at mid-range (5 or 6). Set the Ventilation Control at CLOSED and the Energy Saver Switch* at NORMAL or SAVE position.

To adjust air direction

Up and down

UP-AND-DOWN—

Y

AIR DIRECTION

 

Three separate banks of up-and- down air direction louvers are controlled by fingertip pressure on the louvers. They regulate air discharge upward, downward or straight out.

Side to side

OFFON

m

CIRCUWIRE

Some models have a Circulaire Switch. For fixed side-to-side air direction, slide the Circulaire Switch to ON until the desired air direction is obbined, then move it to OFF.

For extreme temperatures

For greatest economy and best performance, we suggest you set the Selector Switch at HIGH COOL in extremely hot weather.

*On models so equipped

For continuous side-to-side air circulation, set the Circulaire Switch to ON and leave it there.

Other models have two separate banks of side-to-side air direction louvers with separate tabs to let you direct discharged air to the right, to the left, or straight ahead.

4

Image 4
Contents Ak ContiYioner Hportant Safety Instructions Save time and money. Before you request serviceHelp us Help you Ene~y-savi~ tipsOpemting Your Air Conditioner Controk Selector SwitihThermostat Control Ene~y Saver SwikhOpemting Your Air Conditioner Controb Care and Cleaning Grille & CabinetCondemer Coils Air FilterIf You Need Service Problem Possible Cause and RemedyPlease Read Carefully How to connect electricity Imtallation ImtructiomElectrical Safetv Electrical requirementTook Needed Window Requirement@Window Mounting Window RequirementRemove the Chassis Instill Top Angle and Side RetainersInstall Window hck and Sash Seal Install Support BrackeBcate Cabinet in Window Etiend Window Hller PanekTook Required Additional MaterialsPreDare Wall ODeninp CabinetWarranty

AED18, AES18, AES15, AES23 specifications

The GE AES15, AES18, AED18, and AES23 are part of General Electric's innovative range of advanced energy solutions designed to optimize performance and efficiency in various applications. Each model brings unique characteristics and technologies to meet the diverse needs of industries around the globe.

The GE AES15 is known for its compact design and high energy efficiency, making it ideal for applications requiring reliable power in limited spaces. One of its standout features is the advanced compressor technology, which enhances performance while reducing energy consumption. Additionally, the AES15 is equipped with intelligent controls that enable seamless integration into existing systems, ensuring optimal operation and monitoring.

Moving to the GE AES18, this model offers an increased capacity and further improved efficiency than its predecessor. The AES18 incorporates variable speed drive technology, allowing it to adjust its output in real time based on demand. This capability not only enhances energy savings but also reduces wear and tear on the system, leading to lower maintenance costs. The robust construction of the AES18 makes it suitable for industrial environments, ensuring long-lasting performance.

The AED18 model brings a specialized focus on durability and versatility. Designed for harsh operating conditions, it features rugged components and advanced thermal management systems. The AED18 is particularly effective in high-load scenarios, excelling in applications that demand continuous operation. Its modular design allows for easy upgrades and customization, catering to specific installation requirements.

Finally, the GE AES23 represents the pinnacle of GE’s energy solutions, featuring an impressive power output and the latest in sustainable technologies. The AES23 harnesses intelligent grid technology, facilitating better energy management and integration with renewable sources. With enhanced monitoring solutions, operators can easily track performance metrics and optimize operations in real time.

In summary, the GE AES series, including the AES15, AES18, AED18, and AES23, showcases impressive features tailored to various industrial applications. From compact designs and variable speed drives to rugged construction and intelligent grid integration, these models exemplify GE’s commitment to advancing energy efficiency and reliability. As industries continue to seek sustainable energy solutions, the AES series stands out as a versatile and powerful choice in the market.