Samsung MH026FNCA service manual 11-5 Q & a for Non-trouble

Page 104

11-5 Q & A for Non-trouble

Classification

Class

Description

 

 

 

 

Q

The cooling is weak.

 

 

 

 

A

When it is hot outside, its cooling capacity decreases due to the increase of the ambient temperature.

 

 

When the dust filter gets blocked or warm outside air gets in, the cooling capacity will decrease. So,

 

 

make sure to clean the dust filter frequently, prevent heat loss by closing the doors and insulate the

 

 

cooling area by using curtains, blinds, shades or window tinting.

 

 

 

 

Q

The cooling is good generally. But, it gets weak when it is considerably hot.

 

 

 

 

A

It occurs when the outdoor unit is exposed to direct sun light and heat-up air is not ventilated well.

 

 

So, set up a sunblind over the outdoor unit and keep stuff away from the unit to increase the ventila­

 

 

tion. When the cooling capacity decreases during a heat wave, clean the heat exchanger of the out­

 

 

door unit or spray some cold water to the heat exchanger to increase the cooling capability.

Cooling

 

 

Q

The cooling is weak. Does it need refrigerant charging?

 

 

 

 

 

A

It is not correct charging refrigerant regularly. Except that you have moved in several times or the

 

 

connection pipes are broken, the refrigerant does not run low. So, when refrigerant is additionally

 

 

charged, it could be costly and cause a product's failure. When the refrigerant leaks, all of it will

 

 

escape in a short time resulting in cooling failure and no water coming out of the drain hose. So, if

 

 

water comes out from the drain hose, it indicates the normal operation of the product and it does not

 

 

need refrigerant charging.

 

 

 

 

Q

It fails to do cooling.

 

 

 

 

A

When the air conditioner is set to Ventilation or the desired temperature is set higher than the current

 

 

temperature, it fails to do cooling. In this case, select Cooling or set the desired temperature lower.

 

 

 

 

Q

It floods the floor.

 

 

 

 

A

Place the drain hose properly. When it is not placed properly, the drain water would flow back flooding

 

 

the floor. So, straighten out the drain hose for the water to be drained well.

 

 

 

 

Q

Water drips at the drain connection (service valve) of the outdoor unit.

 

 

 

 

A

When a glass bottle is taken out of the refrigerator, moisture gets condensed on its surface due to the

 

 

temperature differences. The same principle applies to the air conditioner. When cold refrigerant goes

 

 

through the copper tube, moisture gets condensed on the surface of the tube and the connection

Leakage

 

areas. To prevent the water condensation, the pipes are insulated. But, the connection areas of the

 

outdoor unit are not insulated for the purpose of maintenance or repair, and water gets condensed due

 

 

 

 

to the temperature differences and drips down. Generally, it evaporates right away. But, when it drips

 

 

much during muggy days, put a water pan on the floor.

 

 

 

 

Q

It leaks even though a drain pump is used.

 

 

 

 

A

It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump

 

 

and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer.

 

 

Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump

 

 

problems.

 

 

 

 

Q

Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache.

 

 

 

 

A

There are no components in the air conditioner irritating the eyes and sending out chemical smells.

Smells

 

But, when the air conditioner is turned on, other smell sources are sucked into the air conditioner and

 

 

get out of it. So, find and root out the smell sources. Generally, it occurs at a interior renovated place,

 

 

a pharmacy, a gasoline handling place, a tire shop, a second-hand book shop or an electronic

 

 

 

Samsung Electronics

11-6

Image 104
Contents Free Joint Multi AIR Conditioner Contents 10-1 Precautions Disposing of the unit OthersProduct Specifications Feature of ProductMH026FNCA Product SpecificationsModel Product Specificationscont MH026FECA MH035FECA MH052FECA Qfgn &#$ %##+VGO 176&11470+6QFG0Q Accessory and Option SpecificationsIndoor Unit Accessories Descriptions Code-No RemarkIndoor Unit Accessoriescont DescriptionsCable-tie Unit$# Outdoor Unit AccessoriesTCKP2NWI1WV Transmitter Unit Accessories Cable-tie DB65-10088B124#6+10 +/4 674$1 &J@KKN2JEPGuetkrvkqp Indicators Abnormal conditions Operating Blue RedBreakaway of Cond MID sensor Display RemarkOutdoor Unitcont Feature Setting Option Setup MethodEnter the Option Setup mode Feature Display Unit operation test-run Error ModePressing the ON/OFF button Technical Bulletin Table of the option code  5VCPFCTF  Disassembly and Reassembly Necessary ToolsProcedure Remark Indoor UnitUnlock 3 hooks to fix Panel Front Tray Drain Back-Body Parts Procedure Remark 2 MH026FECA/MH035FECA Parts Procedure Drain Pan Parts Procedure Disassemble if after disassembling the Cabinet Top Motor Parts Procedure 3 MH052FECA Parts Procedure Detach the Motor Wire Connected to PCB and Capacitor Parts Procedure Samsung Electronics Detach the Evaporator from the set Control Samsung Electronics Outdoor Unit 1 MH050FXCA2ASamsung Electronics Detach the Compressor 2 MH080FXCA4A Parts Procedure Remark Use Monkey Spanner TLHK@A@3EASO=J@-=NPOEOP 2CTVU.KUV 2 MH052FNCA Samsung Electronics#50# 0Q QFG0QGuetkrvkqp 5RGEKHKECVKQP 3 MH026FECA/MH035FECA Parts List 50#4 MH052FECA #55 %#$+$#5 #55 5%%/6         %##    13-1 #$ Wiring Diagram @KKN2JEPĠ?KJP # aMH050FXCA2A MH080FXCA4A Schematic Diagram Mhfeca PCB Diagram Main PCBIndoor Unit02- Ġ&J@KKN2JEP Ġ?KJP Mhfnca@ 4 # $% ‘ + = Q *&+ Ġ,QP@KKN2JEP #5 *%#5 Troubleshooting Checking and Testing operations Reset buttonPipe Checking Operation Auto Addressing Mode Button K1 timesMode Function Move dip switch n1 of SW02 Type Picture ModelInstallation Test Mode with all indoor units functioning Connected 0=A1=B2=C3=DContents Auto address setting Operation case Try-run Check Error Fault Diagnosis by Symptom Basic Check FlowBasic Check Flowcont Checking Outdoor Controller LED1 Red Always onLED3 Yellow OFF Hardware troubleMeasuring point Normal value Index Value RemarkChecking Temperature sensor  DA?GEJC3 -ELAI=P?DEJCProcedure PCB InspectionSelecting Area for Installation Indoor Unit#FFKPITGHTKIGTCPV Remote Control UnitOutdoor Unit Connecting Up and Purging the Circuit MH050FXCA2AMH080FXCA4A Refrigerant Refill 10-3-1 MH050FXCA2A10-3-2 MH080FXCA4A 5#5CA*%8#5C4A Ncuu #VKPUVCNNCVKQP #VUGTXKEGFlare Nut Fixing Torque Outer diameter Torquekg..cm Fixing Torque Final TorqueRelocation of the air conditioner Pump down Procedure10-6-1 MH050FXCA2A 10-6-2 MH080FXCA4A Index for Model Name 052 O O O07 / O O O Refrigerating Cycle Diagram Samsung Electronics 11-4 Power/Heat Pressure & Capacity markCal/s Kcal/h Btu/h Kg . m/s Ib . m/s 544.411-5 Q & a for Non-trouble For Non-trouble Class Description Remote controller wont operate Is it possible to install the outdoor unit outside?Cleanness Common sense of refrigerationAir supplier AirElectronics

MH026FNCA specifications

The Samsung MH026FNCA is an innovative solution designed to meet the diverse needs of residential and commercial spaces. As a part of Samsung's advanced lineup of air conditioning systems, this model exemplifies the brand's commitment to quality, efficiency, and cutting-edge technology. With an array of features, the MH026FNCA stands out as an ideal choice for users seeking reliable climate control in their environments.

One of the standout characteristics of the Samsung MH026FNCA is its energy efficiency. Equipped with a powerful inverter technology, it adjusts the compressor speed to maintain the desired temperature with minimal energy consumption. This not only helps in reducing electricity bills but also contributes to a more sustainable lifestyle, making it an eco-friendly choice for consumers.

The MH026FNCA also incorporates a multi-stage filtration system, which significantly improves indoor air quality. This system includes a washable pre-filter and a high-performance HEPA filter that captures dust, allergens, and other microscopic particles, ensuring that the air circulated in the room is fresh and clean. This feature is particularly beneficial for those who suffer from allergies or respiratory issues.

In terms of usability, the Samsung MH026FNCA is designed with convenience in mind. It comes with a user-friendly remote control that allows users to adjust settings effortlessly from a distance. Additionally, its smart technology enables compatibility with various smart home systems, offering the ability to control the unit via smartphone apps or voice commands for seamless integration into modern living spaces.

The robust build quality of the MH026FNCA enhances its reliability, ensuring long-lasting performance even in demanding conditions. With a sleek design and compact size, it can easily blend into different interior decors while providing quick and effective cooling or heating, depending on the season.

Furthermore, the MH026FNCA features advanced noise reduction technologies, making it one of the quietest models in its class. Users can enjoy a peaceful environment without the distraction of loud operational sounds, making it ideal for bedrooms, offices, and public spaces where tranquility is essential.

Overall, the Samsung MH026FNCA is a testament to innovation in air conditioning technology, combining energy efficiency, advanced filtration, smart features, and aesthetic appeal. For those in search of an effective climate control solution, this model sets a high standard that meets various consumer requirements without compromising on performance or comfort.