5.After cutting out the required area install the housing using the hanging brackets or housing mounting tabs as described previously.

Ducting

Note: All ducting must comply with local and national building codes.

1.Connect the ducting to the fan's duct collar. Secure in place using duct tape or screw clamp. Always duct the fan to the outside through a wall or roof cap. To ensure maximum air delivery, keep the length of duct and number of elbows to a minimum.

Electrical Wiring

WARNING: POWER MUST BE PROVEN DISCONNECTED BEFORE STARTING INSTALLATION, INSPECTION OR MAINTENANCE! FAILURE TO DO SO MAY CAUSE SERIOUS INJURY, DEATH AND/OR PROPERTY DAMAGE.

Caution: Make sure power is switched off at service panel before beginning this installation.

Note: All wiring must comply with local and national codes. You must ground this unit.

1.Run wiring from the wall switch (not provided) to the housing electrical compartment, 1 neutral (white), 1 ground (green or bare copper), and 3 hot (black leads connected to the switch). Make sure you identify which wire is for which component. Secure the electrical wires to the housing with an approved electrical connector (make sure you leave enough wiring in the box to make the connection to the fan’s receptacle and the light’s receptacle).

2.From where you have access to inside the fan’s junction box, connect the white wire from the house to the white wire of the fan’s receptacle and the light’s receptacle, then connect one black wire to the house wire intended for fan control, connect the yellow wire to the house wire intended for main lighting control and connect the red wire to the house wire intended for night lighting control (use approved electrical connectors). Connect the ground wire to the green ground screw in the fan’s junction box. Replace the fan’s wire compartment cover.

Completing the Installation

1. After you have installed the housing in the ceiling,

run ducting from the unit to the outside and have made the necessary electrical connections you can reinstall the light housing, motor plate and blower in the fan housing (Fig. 3). Plug the fan’s blower assembly into the fan’s receptacle before you lift

the motor plate/blower assembly up into possition and secure the motor plate using the screw removed earlier.

Plug the light housing into the intended wiring harness after the motor plate is secure. Rotate the blower wheel by hand to ensure it revolves freely.

2.Install lamps, 100 watt maximum for light and 7 watt maximum for night light.

3.To install the grill, squeeze the two ends of each spring fastener together and insert each into the slots on the motor plate. Push the grill up to the ceiling.

Troubleshooting Guide

Trouble

Probable Cause

Suggested Remedy

1.

Fan does not operate when the switch is on.

1a.

A fuse may be blown or a circuit tripped.

1a.

Replace fuse or reset circuit breaker.

 

 

1b.

Connector plug from motor is not plugged in.

1b.

Turn off power to unit. Remove Grill and plug

 

 

 

 

 

 

 

motor into receptacle in housing. Restore power

 

 

 

 

 

 

 

to unit.

 

 

 

 

 

 

 

 

2.

Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2.

Check for any obstructions in the ducting. The

 

 

 

 

 

 

 

most common are bird nests in the roof cap or

 

 

 

 

 

 

 

wall cap where the fan exhausts to the outside.

 

 

 

 

 

 

 

 

3.

Fan is operating is louder than normal.

3a.

Motor is loose.

3a.

Turn off power to unit. Remove grill and check

 

 

 

 

 

 

 

that all screws are fully tightened. Restore

 

 

 

 

 

 

 

power to unit.

 

 

3b.

Fan blade is hitting housing of unit.

3b.

Call your dealer for service.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warranty

WHAT IS COVERED?

Full Five Year Parts Warranty from date of original proof of purchase. We will provide, free of charge, a replacement part that fails due to manufacturing defect in material or workmanship, when installed and used as directed in the User’s Guide.

This warranty is extended to the original purchaser for products purchased for ordinary home use.

WHAT IS NOT COVERED?

Installation services or service trips to your home to teach you how to use the product.

Labor costs or the cost of replacement components as part of routine maintenance.

Failure or defects in product arising from Improper installation

If you have an installation problem, contact your dealer or installer. You are responsible for providing adequate electrical, exhausting and other connecting facilities. See the Installation Instructions provided with this product for electrical, exhaust and connection details.

Replacement of house fuses or resetting of circuit breakers.

Failure of the product if it is used for something other than the intended purpose of manufacturer or used commercially.

Damage to the product caused by accident, fire, floods, acts of customer, or acts of God.

This warranty contains the sole and exclusive warranty of GE for claims based on defects in these products. Upon the expiration of the warranty period, all such liability shall terminate. There are no other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.

IN NO EVENT SHALL GE BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES, SUCH AS, BUT NOT LIMITED TO, LOSS OF PROFIT OR REVENUES, LOSS OF USE OF THE PRODUCTS OR ANY ASSOCIATED EQUIPMENT, DAMAGE TO ASSOCIATED EQUIPMENT, OR COST OF SUBSTITUTE PRODUCTS.

IN NO EVENT, SHALL GE’S LIABILITY TO BUYER FROM THE SALE OF THESE PRODUCTS EXCEED THE PRICE OF THE DEFECTIVE PRODUCT SOLD AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Read your User’s Guide. If you have any questions about operating the product, please contact your dealer.

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

Image 2
Contents Important Safety Instructions Mounting the Housing New ConstructionTroubleshooting Guide Electrical WiringCompleting the Installation Warranty

BFL125UQ specifications

The GE BFL125UQ is a robust and versatile circuit breaker designed for residential and commercial applications, ensuring both safety and reliability in electrical systems. This model has gained recognition for its advanced features and technologies that meet the demands of modern electrical installations.

One of the standout characteristics of the GE BFL125UQ is its 125-amp rating, which makes it suitable for a variety of load requirements. This circuit breaker is designed to protect lighting, receptacles, and other circuits from overloads and short circuits. The BFL125UQ’s thermal-magnetic design provides dual protection, responding to both slow surges and fast short-circuit events.

The GE BFL125UQ incorporates an easy-to-read trip indicator, allowing users to quickly assess the operational status of the circuit breaker. This feature is particularly useful during troubleshooting or maintenance, as it provides immediate feedback whether the breaker has tripped due to an overload or another fault.

Another prominent technology featured in the BFL125UQ is its compact design, which optimizes space within electrical panels. This is crucial in environments where space is at a premium, allowing for more circuits without sacrificing performance or safety. Its compatibility with a range of panel boards further enhances its applicability across different installations.

The BFL125UQ also emphasizes safety through its dielectric strength, ensuring reliable performance even under challenging conditions. This circuit breaker is UL listed, meeting stringent safety standards and providing users with peace of mind regarding its reliability.

In addition, the GE BFL125UQ incorporates user-friendly installation features. Its mounting mechanism simplifies installation for electricians, minimizing labor time and costs. The breaker’s robust construction ensures long-term durability, making it a preferred choice for both new constructions and upgrades in existing electrical systems.

Overall, the GE BFL125UQ circuit breaker stands out for its advanced protective features, compact design, and user-friendly installation. Its ability to safeguard electrical systems effectively while ensuring ease of use makes it a popular choice among professionals in the industry.