Xantrex Technology ENET-XFR RS-232 Mode Troubleshooting Tips, 11 RS-232 Mode Tips, TM-XR9B-01XN

Models: ENET-XFR ENET-XFR3

1 100
Download 100 pages 7.21 Kb
Page 73
Image 73
RS-232Mode Troubleshooting Tips

Troubleshooting

RS-232Mode Troubleshooting Tips

Table 3-11 RS-232Mode Tips

 

 

 

CannotSymptomestablish

PossibleUsing straightCausesthrough

CorrectiveUse a Null ModemActionscable

communication

RS-232cable instead of

 

 

Null Modem cable

 

 

Loose cables

Ensure that the cables are securely connected to

 

 

the computer and the power supply.

 

Baud rate mismatch

Select a baud rate that matches the instruments

 

 

settings. See “Baud Rate Selection” on page 2–

 

 

18 for details changing this setting.

 

Trying to communicate via

Most computers have two COM ports, COM1

 

the wrong COM port

and COM2, so ensure you have selected the

 

 

correct COM port.

 

The interface card is

Reconfigure the interface card for RS-232

 

configured for Ethernet

communications. See “Configuring for Ethernet

 

communications

or RS-232” on page 2–12 for details.

 

 

 

RS-232and/or Ethernet Mode Troubleshooting Tips

Table 3-12RS-232 and/or Ethernet Mode Tips

 

 

 

 

 

 

 

InstrumentSymptomnot

PossibleThe unit isCausesin local mode

CorrectivePut the unit intoActionsremote mode by sending the

responding to new

 

command REN ON.

user settings

 

 

 

 

 

The output is

The output is off

Send the command OUT ON

displaying zero

 

 

volts and zero amps,

The output has tripped due

the condition that has caused the fault,

but the setpoints are

to an OVP, or foldback

and send the command RST

non-zero

protection event

 

 

 

 

TM-XR9B-01XN

3–23

Page 73
Image 73
Xantrex Technology ENET-XFR manual RS-232 Mode Troubleshooting Tips, RS-232 and/or Ethernet Mode Troubleshooting Tips, 3-23