Xantrex Technology ENET-XFR3 manual Baud Rate Selection, 6 Jumper J2 Settings for Baud Rate

Models: ENET-XFR ENET-XFR3

1 100
Download 100 pages 7.21 Kb
Page 40
Image 40
Baud Rate Selection

Installation and Configuration

Baud Rate Selection

Serial transmission sends and receives data in bit streams at fixed bit rates. Both the computer and the interface must have the same bit rate setting for proper communication. The default baud rate is 9600. We recommend that you do not change this setting. If the setting must be changed, use Table 2-6to select the correct jumper positions. You will need to remove the cover to change any jumpers. See “Changing Internal Jumpers” on page 2–8.

Table 2-6Jumper J2 Settings for Baud Rate

9600BaudRateB3closed

B2closed

B1closed

4800

open

closed

closed

 

 

 

 

2400

closed

open

closed

 

 

 

 

1200

open

open

closed

 

 

 

 

600

closed

closed

open

 

 

 

 

300

open

closed

open

 

 

 

 

150

closed

open

open

 

 

 

 

75

open

open

open

 

 

 

 