Table 3-10 Ethernet Mode Tips

SymptomAble connect to the device server

(Ethernet Bridge), but unable to control r receive a response from the power supply

PossibleCauses

Corrective Actions

The Eth rnet/RS-232

Reconfigure the interface card for Ethernet

Interface card is configured

c

mmun cations. See page 2–12for details.

for RS-232 communications

 

 

The embedded Ethernet

Ensure that the baud rate for the Ethernet Bridge

Bridge is incorr ctly

is set for 9600 by connecting to its HTTP server

c nfigur d

and checking its Serial Port settings. This can be

 

d

ne by entering the device's IP address into a

 

web brows r and using the correct username and

 

password to ac ess the device server. See

 

“Configuring Ether et Bridge” on page 2–15 for

 

m

information.

 

Ensure hat the baud rate setting on the interface

 

card is set to 9600 - ee the “Baud Rate

 

Selection” on page 2–18 for details.

 

 

 