Command

Command Reference

Table 3-7Command Reference

UNMASK?

Asks for the supply's fault conditions which are currently enabled (unmasked).

 

R ponse: UNMASK <fault mask> where fault mask is the decimal equivalent of

 

the total bit weights for the operating conditions as listed in the status and fault

 

registers See “Accumulated Status, Status, and Fault Registers” on page 3–17.

 

 

VDATA

Calculates a d records the slope and offset for programmed voltage using VLO

<Vlo>,<Vhi>

and VHI data. Set CMODE ON before using this command. See also the

 

calibration procedures in Chapter 4.

 

<Vlo> and <Vhi> are in <voltage> format.

 

 

VHI

In response to this command, the power supply sends a programmed voltage value

 

to the ou put terminal. This value is at the high end of the power supply’s voltage

 

range and is read by an external device connected as part of the calibration

 

procedure. Refer to this value as VHI and record it to use as input with the VDATA

 

command. Set CMODE ON before using this command. See also the calibration

 

procedures in Chapter 4.

 

 

VLO

In response to this command, the power supply sends a programmed voltage value

Command

to the ou put terminal. This value is at the low end of the power supply’s voltage

range and is read by an external voltmeter connected as part of the calibration

Descriptionprocedure. Refer to this value as VLO and record it to use as input with the

 

VDATA command. Set CMODE ON before using this command. See also the

 

calibration procedures in Chapter 4.

VMAX <voltage> Sets an upper soft limit on the supply’s programmed output voltage. If the soft limit is exceeded, or if the soft limit value is lower than the present output voltage setting, the supply will ignore the command, turn on the ERR LED, and set the ERR bit in the accumulated status register.

Range: 0 to model maximum output voltage (VMAX)

Initial value: model VMAX

VMAX?

Asks for the supply’s soft voltage limit setting.

 

Response: VMAX <voltage>

 

 

VOUT?

Measures the supply’s actual voltage output using the built-in voltage readback

 

circuitry.

 

Response: VOUT <voltage>

 

 

VRDAT

Calculates and records the slope and offset for readback voltage using VRLO and

<Vlo>,<Vhi>

VRHI data. Set CMODE ON before using this command. See also the calibration

 

procedures in Chapter 4 .

 

<Vlo> and <Vhi> are in <voltage> format.

 

 