This procedure can be used as a quick reference for those familiar with the configuration requirements for the Ethernet/RS-232 Interface as installed in the DC power supply. For those who want more information, each step refers to more detailed procedures located in subsequent sections. Execute each step of the procedure in the sequence given.

Table 2-4RS-232Setup Procedure

1Step

DescriptionMode

ActionConfigure for RS-232

ReferenceSee “Configuring for Ethernet or RS-

 

Configuration

communications.

232” on page 2–12.

 

 

 

 

2

Baud Rate

Select transmission speed.

See “Baud Rate Selection” on

 

Selection

(Default 9600)

page 2–18.

3

Flow Control

Select flow control ON or OFF.

 

Selection

(Default is OFF) If flow control is

 

 

set ON, choose software-based

 

 

XON/XOFF or hardware-based

 

 

RTS/CTS communication control.

See “Flow Control Selection” on page 2–19.

4

Remote/Local

The factory default is PON REM.

See “Remote/Local Operation” on

 

Operation

 

page 2–20.

 

 

 

 

5

RS-232

Connect the RS-232 cable assembly

See “Power Supply Settings” on

 

Connection

to the RS232 connector on the

page 2–23

 

 

supply.

 

 

 

 

 

6

User Signal

Configure and use the user line

See “User Lines Connector” on

 

Connector

connector signals, if required.

page 2–26.

 

 

 

 

7

Power ON

Power on the unit.

See “Additional User Options and

 

 

 

Settings” on page 2–24 and “User

Signals” on page 2–26 for information about Local/Remote OVP, TTL Shutdown, and auxiliary connector user signals.

8

Power Supply

Configure the controller’s operating

 

Settings

parameters to match the power

 

 

supply settings.

See “Power Supply Settings” on page 2–23.

9

Test

Test the link by communicating with Example: VSET2;ISET1

 

 

the power supply.

This command string sets power

 

 

 

supply voltage to 2V and its current

 

 

 

limit to 1A.

 

 

 

See “Operation”.

 

 

 

 

TM-XR9B-01XN