Command Reference

Table 3-7Command Reference

 

 

 

Command

Description

 

FOLD?

Asks for the supply’s present foldback setting.

 

R ponse: FOLD <mode> where mode is:

 

0 (OFF) or

 

 

 

1 (CV or Co

stant Voltage mode) or

 

2 (CC or Co

stant Current mode)

GTL

Go to local. Returns the power supply to local control. See LLO (Local Lockout).

 

S e also“Remote/Local Operation” on page 2–20.

HOLD <1/ON>,

Enables or disables voltage/current setting hold mode for the supply. When

<0/OFF>

HOLD ON is specified, hold mode is enabled so that all voltage and current

 

settings which would normally be implemented by the supply are held until a TRG

 

(trigger) c

mmand is received. This feature allows you to synchronize the

 

operat

f several supplies.

 

Initial value: HOLD OFF or HOLD 0

 

 

HOLD?

Asks for the present hold mode setting.

 

R ponse: HOLD 0 (OFF or disabled) or HOLD 1 (ON or enabled)

 

 

ID?

Asks for the power supply model and the master EPROM version.

 

R ponse: ID <model name><version>

 

 

IDATA

Calculates and records the slope and offset for programmed current using ILO and

<Ilo>,<Ihi>

IHI data. Set CMODE ON before using this command. See also the calibration

 

procedures in Chapter 4.

 

<Ilo> and <Ihi> are in <current> format.

 

 

IHI

In response to this command, the power supply sends a programmed current value

 

to the output terminal. This value is at the high end of the power supply’s current

 

range and is read by an external device connected as part of the calibration

 

procedure. Refer to this value as IHI and record it to use as input with the IDATA

 

command. Set CMODE ON before using this command. See also the calibration

 

procedures in Chapter 4.

 

 

ILO

In response to this command, the power supply sends a programmed current value

 

to the output terminal. This value is at the low end of the power supply’s current

 

range and is read by an external device connected as part of the calibration

procedure. Refer to this value as ILO and record it to use as input with the IDATA command. Set CMODE ON before using this command. See also the calibration procedures in Chapter 4 .

TM-XR9B-01XN

3–11

Page 61
Image 61
Xantrex Technology ENET-XFR3 manual AlsoRemote/Local Operation on