Power Supply Settings

Local Lockout (LLO) Command

Use the Local Lockout command to disable the LOCAL button on the power supply front panel. With LLO in effect, you cannot return to local control by pressing the front panel LOCAL switch. You can still return to local mode by sending the Go to Local (GTL) command. However, to turn off LLO and return the power supply to local mode, send the REN OFF command. Only the REN OFF command will remove the LLO condition.

Example:

LLO

Set Local Lockout

GTL

Return the power supply to local mode.

 

Local Lockout is still in effect

REN OFF

Turn off Local Lockout and return the

 

power supply to local mode

Power Supply Settings

For serial communication, the computer and the Ethernet/RS-232 Interface must share the same communication settings. Make sure that the settings of the computer and of the power supply agree with those shown in Table 2-11.

Table 2-11

Power Supply Settings

 

 

 

 

TransmissionParameter

AsynchronousSetting

 

 

Mode

Full Duplex

 

 

Speeds

75, 150, 300, 600, 1200, 2400, 4800, 9600 (default)

 

 

Parity

None

 

 

Connector

DB9-pin Male

 

 

Start Bit

1

 

 

Stop Bit

1

 

 

Data Bits

8

 

 

Protocols

XON/XOFF

 

RTS/CTS

 

NONE (default)

 

 