Command Reference

Table 3-7Command Reference

 

 

Command

Description

LLO

isables the front panel LOCAL switch. When LLO is in effect you can only

 

return to local mode using the GTL command. You can remove the local lockout

 

with the REN command. See also “Remote/Local Operation” on page 2–20.

MASK

isables the supply's previously unmasked operating conditions from setting bits

<mne ics>

in the fault and status registers. See “Accumulated Status, Status, and Fault

 

R gisters” on page 3–17. Mnemonics are separated from each other by commas

 

and may be sent in any order.

 

Mnemonics: CV, CC, OV, OT, SD, FOLD, ERR, PON, REM, ACF, OPF, SNSP

 

Note: UNMASK NONE = MASK ALL (Initial value)

 

MASK NONE = UNMASK ALL

OUT <1/ON>, <0/ Enables or disables the supply’s voltage/current output. The supply will continue to

OFF>

accept new commands while the output is disabled but these will not be

 

implemented until OUT ON or OUT 1 is received. OUT ON is the default setting.

 

When you start the supply in remote mode, the output is enabled.

 

OUT OFF (or OUT 0) also sets the isolation signal on the rear panel user lines

 

connector, li e 3. You can use the to trip external relays to isolate the power supply

 

from the load.

 

Initial value: OUT ON (or OUT 1) for output enabled

 

 

OUT?

Asks for the present enabled/disabled status of the supply’s output voltage/current.

 

Response: OUT 1 output enabled or

 

OUT 0 output disabled

 

 

OVCAL

Causes the master controller to perform automatic calibration of the supply’s over

 

voltage protection circuitry. Set CMODE ON before using this command. Ensure

 

jumper J65 on the Ethernet/RS-232 Interface PCB is connected for remote

 

operation.

 

 

OVSET

Sets the supply’s over voltage protection trip point in volts (default) or in

<voltage>

millivolts. If the trip point is exceeded, or if the trip point value is lower than the

 

present output voltage setting, the supply will ignore the command, turn on the

 

ERR LED, and set the ERR bit in the accumulated status register. Reset with the

 

RST command.

 

Range: 0 to 110% of model maximum output voltage (VMAX)

 

Initial value: 110% of model VMAX

 

 

OVSET?

Asks for the supply’s present over voltage protection limit.

 

Response: OVSET <voltage>

 

 

TM-XR9B-01XN