Table 3-5Calibration Commands

Operation

Table 3-5Calibration Commands

CMODECommand

DescriptionPlaces the supply into calibration mode.

IDATA

Calculates the slope and intercept for current programming.

 

 

IHI

Sets the current output to the high calibration point.

 

 

ILO

Sets the current output to the low calibration point.

 

 

IRDAT

Calculates the slope and intercept for current readback.

 

 

IRHI

Sets the current output to the high readback point.

 

 

IRLO

Sets the current output to the low readback point.

 

 

OVCAL

Calibrates the over voltage protection (OVP).

 

 

VDATA

Calculates the slope and intercept for voltage programming.

 

 

VHI

Sets the voltage output to the high calibration point.

 

 

VLO

Sets the voltage output to the low calibration point.

 

 

VRDAT

Calculates the slope and intercept for voltage readback.

 

 

VRHI

Sets the voltage output to the high readback point.

 

 

VRLO

Sets the voltage output to the low readback point.

 

Table 3-6Status Commands

 

 

 

 

ASTS?Command

DescriptionAsks for the supply’s accumulated status register.

 

 

FAULT?

Asks for the supply’s fault register for the status preset operating

 

conditions.

 

 

MASK

Prevents the supply's previously unmasked operating conditions

 

from setting bits in the fault register.

 

 

STS?

Asks for the supply’s present status register.

 

 

UNMASK

Enables you to select those supply's operating conditions that you

 

are most interested in monitoring for fault occurrence.

 

 

UNMASK?

Asks for the supply's fault conditions which are currently enabled

 

(unmasked).

 

 