Xantrex Technology ENET-XFR3 manual ASTS?Command, 7 Command Reference, TM-XR9B-01XN

Models: ENET-XFR ENET-XFR3

1 100
Download 100 pages 7.21 Kb
Page 59
Image 59
Command Reference

Command Reference

Command Reference

Table 3-7Command Reference

ASTS?Command

DescriptionAsks for the supply’s accumulated status register. The accumulated status register

 

stores any bit that was entered in the status register since the accumulated status

 

query command (ASTS?) was last used, regardless of whether the condition still

 

exists. The accumulated status register has the same bits, weights, and conditions

 

as the status register. A bit in the accumulated status register will be set at 1 if the

 

corresponding bit in the status register has been 1 (TRUE) at any time since the

 

register was last read. See “Accumulated Status, Status, and Fault Registers” on

 

page 3–17. The ASTS? query clears the status register.

 

Response: ASTS <status mask> where status mask is the decimal equivalent of the

 

total bit weights for the operating conditions as listed in the status register.

 

 

AUXA <1/ON>,

Controls the AUXA output signal level at rear panel connector Pin 7. Active low.

<0/OFF>

Initial value: AUXA 0

 

 

AUXA?

Asks for the present set value of the AUXA output signal.

 

Response: AUXA 0 (OFF) or AUXA 1 (ON)

 

 

AUXB <1/ON>,

Controls the AUXB output signal level at rear panel connector Pin 8. Active low.

<0/OFF>

Initial value: AUXB 0

 

 

AUXB?

Asks for the present set value of the AUXB output signal.

 

Response: AUXB 0 (OFF) or AUXB 1 (ON)

 

 

CLR

Initializes the power supply to its power ON condition. If issued while in local

 

mode, CLR will force power supply settings to register default values as in but

 

these default settings will not come into effect until the power supply is switched to

 

remote mode operation. The CLR commands will clear faults from the fault

 

register. CLR will not reset CMODE.

 

 

CMODE <1/ON>,

CMODE ON places the power supply into calibration mode for processing

<0/OFF>

calibration commands.

 

Initial value: CMODE OFF or CMODE 0

 

 

CMODE?

Asks for the power supply’s calibration mode status.

 

Response: CMODE 0 (disabled)

 

CMODE 1 (enabled)

 

 

TM-XR9B-01XN