User Signals

Installation and Configuration

User Signals

User Lines Connector

Auxiliary User Lines connector, located on the Ethernet/RS-232 Interface rear panel, provides several signals to increase your operating control of the supply. These signals are dependent on the operator's design and uses. The operation of the user lines connector signal requires that you provide external Vcc and ground. Use a standard 8-position telephone jack and data cable to connect to the user lines connector. To locate the connector, refer to the Ethernet/RS-232 Interface subplate drawing in Figure 2-2 on page 2–5. See Table 2-14for pin descriptions. The user lines connector outputs can sink a current of 5mA each. Figure 2-6 on page 2–27shows the portion of the option board schematic which contains the user line connector. Use the schematic as a reference when making input or output connections.

Table 2-14User Signals Connector

 

 

1Pin

FunctionExternal TTL shutdown input signal (See “TTL Shutdown

 

Polarity” on page 2–25)

 

 

2

Polarity signal, open collector (asserted by VSET -x)

 

 

3

Isolation signal, open collector (asserted by OUT OFF)

 

 

4

Fault signal, open collector (asserted when bit set in fault register)

 

 

5

External Vcc, 15V maximum (supplied by connecting and

 

operating an external source)

 

 

6

External ground and shutdown return (supplied by connecting and

 

operating an external source)

 

 

7

Open collector user signal (asserted by AUXA ON)

 

 

8

Open collector user signal (asserted by AUXB ON)

 

 

User Line

Note: On some models, the connector is rotated 180°.