Specifications for XFR 2.8kW with Ethernet/RS-232 Interface Installed

Table A-4XFR 2.8kW 60 V to 600 V

ProgramModelsResolution

60-46

100-28

150-18

300-9

600-4

Voltage

9.3mV

15.5mV

23.2mV

46.4mV

92.7mV

Current

1.4mA

.9mA

.6mA

.3mA

.2mA

OVP

9.3mV

15.5mV

23.2mV

46.4mV

92.7mV

 

 

 

 

 

 

Program Accuracya

150mV

150mV

225mV

225mV

300mV

Voltage

 

±0.3%

±0.35%

±0.35%

±0.35%

±0.35%

Current

80mA

80mA

80mA

75mA

75mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

OVP

600mV

.0V

.5V

.0V

6V

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

9.3mV

15.5mV

23.2mV

46.4mV

92.7mV

Current

1.4mA

.9mA

.6mA

.3mA

.2mA

 

 

 

 

 

 

Readback Accuracya

150mV

150mV

225mV

225mV

300mV

Voltage

 

±0.3%

±0.35%

±0.35%

±0.35%

±0.35%

Current

80mA

80mA

80mA

75mA

75mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

 

 

 

 

 

 

a.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts

TM-XR9B-01XN

A–5

Page 87
Image 87
Xantrex Technology ENET-XFR3 manual 600-4