Specifications
Specifications for XFR 2.8kW with
Table
ProgramModelsResolution |
| ||||
Voltage | 1.2mV | 3.1mV | 5.1mV | 5.1mV | 6.2mV |
Current | 11.3mA | 4.3mA | .6mA | 13.0mA | 2.2mA |
OVP | 1.2mV | 3.1mV | 5.1mV | 5.1mV | 6.2mV |
|
|
|
|
|
|
Program Accuracya | 10mV | 75mV | 75mV | 75mV | 75mV |
Voltage | |||||
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.3% |
Current | 300mA | 165mA | 120mA | 425mA | 110mA |
| ±0.15% | ±0.15% | ±0.15% | ±0.1% | ±0.15% |
OVP | 75mV | 200mV | 330mV | 330mV | 400mV |
|
|
|
|
|
|
Readback Resolution |
|
|
|
|
|
Voltage | 1.2mV | 3.14mV | 5.1mV | 5.1mV | 6.2mV |
Current | 11.3mA | 4.3mA | .6mA | 13.0mA | 2.2mA |
|
|
|
|
|
|
Readback Accuracya | 10mV | 75mV | 75mV | 75mV | 75mV |
Voltage | |||||
| ±0.12% | ±0.12% | ±0.2% | ±0.3% | ±0.3% |
Current | 300mA | 165mA | 120mA | 425mA | 110mA |
| ±0.15% | ±0.15% | ±0.15% | ±0.1% | ±0.15% |
a.Apply accuracy specifications according to the following voltage program accuracy example: Set a model
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.