Specifications

Specifications for XFR 2.8kW with Ethernet/RS-232 Interface Installed

Table A-3XFR 2.8kW 7.5 V to 40 V

ProgramModelsResolution

7.5-300

12-220

20-130

33-85

40-70

Voltage

1.2mV

3.1mV

5.1mV

5.1mV

6.2mV

Current

11.3mA

4.3mA

.6mA

13.0mA

2.2mA

OVP

1.2mV

3.1mV

5.1mV

5.1mV

6.2mV

 

 

 

 

 

 

Program Accuracya

10mV

75mV

75mV

75mV

75mV

Voltage

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

300mA

165mA

120mA

425mA

110mA

 

±0.15%

±0.15%

±0.15%

±0.1%

±0.15%

OVP

75mV

200mV

330mV

330mV

400mV

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

1.2mV

3.14mV

5.1mV

5.1mV

6.2mV

Current

11.3mA

4.3mA

.6mA

13.0mA

2.2mA

 

 

 

 

 

 

Readback Accuracya

10mV

75mV

75mV

75mV

75mV

Voltage

 

±0.12%

±0.12%

±0.2%

±0.3%

±0.3%

Current

300mA

165mA

120mA

425mA

110mA

 

±0.15%

±0.15%

±0.15%

±0.1%

±0.15%

a.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

A–4

TM-XR9B-01XN