Items | Models | Product Description |
247592 | 150 Watt High Pressure Sodium Security Light | |
247595 | 100 Watt Metal Halide Security Light | |
|
|
|
Questions or problems? Before returning to your retailer, call our technical service department at
INSTALLATION INSTRUCTIONS
Estimated Installation Time: 45 minutes Items needed for installation (not included):
• Phillips and flathead screwdrivers
• | 3/8" Socket | • | 3/16" Drill bit |
• | Drill | • | Pliers |
• | Wire strippers/cutters | • | Safety glasses |
• | Silicone caulk | • | Ladder |
• Small box or rag
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suit- ability of the system.
Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.
WARNING: Turn power off at the circuit breaker or fuse.
1.Select a location on a flat wall with structurally sound wood and from 10 to 25 feet from the ground. The wood should be at least one inch thick to safely secure the fixture.
2.Attach the cover plate using two large machine screws.
3.Using the mounting bracket as a template. Hold it at the desired mounting location (making sure the bottom is level), and mark four mounting holes. We suggest drilling 3/16" pilot holes for the lag screws.
4.Put the two top lag screws through their holes in the mounting bracket and hold them in place while you push the gasket onto these lag screws. Start these two screws into the two top pilot holes.
5.Start the other two lag screws, and then tighten all four screws.
6.Hang the fixture on the mounting bracket using the slot in the cover plate.
7.Twist the fixture wires to the supply wires (black to black, white to white, and the bare fixture wire to the supply ground wire).
8.Make sure the wires do not get pinched, and swing the fixture up so the base fits tightly against the gasket. Push the pin through the hole at the top near the gasket, and into the mating loop in the mounting bracket. You may need to tap the pin to seat it all the way down.
9.Secure the fixture with the small machine screw going through the cover plate and into the mounting bracket.
10.Install bulb. Bulb rating must match the rating of the fixture. Model 9272: 150 Watt high pressure sodium type S55 bulb. Model 9274: 100 Watt metal halide type M90/O open rated bulb.
11.Hold the lens and wire cage up to the fixture and align the clips on the wire cage with the protrusions in the housing. Hook the clips over these protrusions and snap the clips closed to hold the lens and wire cage in place.
12.Loosen the screw in the center of the photocontrol socket two turns. Twist the socket so that the arrow points north. Note: There is a stop to prevent the socket from turning all the way around. If you have trouble turning the socket, try turning it the other direction. Retighten the screw in the center of the socket.
13.Align the photocontrol (it will only
14.Caulk fixture mounting surface with silicone weather sealant
To test operation during the daytime, cover the photocontrol with a small box or rag. Turn the power on. Light should turn on and reach full brightness within ten minutes. Remove the box or rag to expose the photocontrol to daylight. Light should turn off within two minutes. With the photocontrol exposed, the light will operate automatically – on at dusk and off at dawn.
Housing | Photocontrol |
| |
| Pin |
Lag Screw
(4) Mounting
Bracket
Cover
Bulb Plate
Gasket
Lens
Package Contents and Fixture Assembly
© 2008 HeathCo LLC |